Starting Circuit - APRILIA RS 50 Workshop Manual

Hide thumbs Also See for RS 50:
Table of Contents

Advertisement

Electrical Equipment
CHECKING DATA
CHECKING THE GENERATOR
Disconnect the yellow wire from the regulator.
Start the engine and increase its speed to 6,000 rpm.
Using a multimeter as an a.c. voltmeter, check that:
voltage between yellow wire and generator earth is
greater than 35 V.
Using a multimeter as an a.c. ammeter, check that:
current between yellow wire and generator earth is
greater 5 A.
CHECKING THE BATTERY
No-load voltage: 12.5 ± 1 V
Electrolyte density: 1.26 at 20° C (68° F)
Check the level of the electrolyte and if necessary top
up with distilled water.
Check for any signs of sulphation and if necessary
replace.

STARTING CIRCUIT

Refer to the paragraph LOCATION OF COMPO-
NENTS.
ELECTRICAL DIAGRAM
Locked
positive
5)
Battery
6)
Starting relay
16)
Start button
34)
Starter motor
chap. 6
16
V/R
B
R
+
-
5
G/R
85
87
30
R
86
6
B
Release 00
2000-11
RS 50
34
M
6-9