ARTHUR HOLM Dynamic2 AH12D216A User Manual page 29

Hdcp compliant retractable monitors for furniture integration
Table of Contents

Advertisement

AHnet PROTOCOL
Picture Commands
COMMAND
DESCRIPTION
FA XX 15 00 00
ASK FOR BACKLIGHT LEVEL
FA XX 16 00 00
ASK FOR CONTRAST LEVEL
FA XX 17 00 00
ASK FOR BRIGHTNESS LEVEL
XX
Number of the monitor address.
Up to 30 monitors for each RS422 BUS
ZZ
Level of the function selected (00 – 99 Dec)
COMMAND
DESCRIPTION
FA XX 15 01 ZZ
SET BACKLIGHT LEVEL
FA XX 16 01 ZZ
SET CONTRAST LEVEL
FA XX 17 01 ZZ
SET BRIGHTNESS LEVEL
XX
Number of the monitor address.
Up to 30 monitors for each RS422 BUS
ZZ
Level of the function selected (00 – 99 Dec)
To send an order to all the monitors, you must use the address:
249 Dec. (Byte1)
F9 Hex. (Byte1)
In this case, the units do not send a reply.
29
RESPONSE
FB XX 15 00 ZZ
FB XX 16 00 ZZ
FB XX 17 00 ZZ
RESPONSE
FB XX 15 01 ZZ
FB XX 16 01 ZZ
FB XX 17 01 ZZ

Advertisement