ARTHUR HOLM DB2Share User Manual

Hdcp compliant retractable monitors including dynamicshare
Hide thumbs Also See for DB2Share:

Advertisement

Quick Links

User Guide
DB2Share
HDCP compliant retractable monitors including DynamicShare
Technology Serving Desing
Danish craftmanship
Mediterranean soul

Advertisement

Table of Contents
loading

Summary of Contents for ARTHUR HOLM DB2Share

  • Page 1 User Guide DB2Share HDCP compliant retractable monitors including DynamicShare Technology Serving Desing Danish craftmanship Mediterranean soul...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS EC REGULATIONS AND SECURITY SAFETY INSTRUCTIONS SYSTEM DESCRIPTION CONTROLS OSD MENU INPUT CONNECTORS DYNAMICSHARE DYNAMICSHARE INSTALLATION AHNET PROTOCOL EXTERNAL SHARE CONTROL SYSTEM INFORMATION ON DISPOSAL WARRANTY TERMS AND CONDITIONS...
  • Page 4 WELCOME Thank you for purchasing an ARTHUR HOLM product. Our product range has been designed for a seamless integration and for a maximum reliability. Please, read this installation and operating instructions carefully and keep them in a safe place for future reference.
  • Page 5 ABOUT US The Company Arthur Holm has its origins in the Danish furniture designer Jorgen Alex Jensen, who was active during the sixties and the seventies. His design inspiration and his concept of ergonomics have been continued by his family, who is the design force behind Arthur Holm product range. The...
  • Page 6: Ec Regulations And Security

    EC REGULATIONS AND SECURITY ATTENTION: Do not disassemble or modify the device in any way. This symbol warns of the presence of dangerous un-insulated voltages inside some of the components, of sufficient magnitude to expose people to risk of electronic shock. This symbol draws attention to important use and maintenance instructions in the manual that accompanies the unit.
  • Page 7 SAFETY INSTRUCTIONS Wiring connected to hazardous voltage requires installation by qualified personnel or the use of ready-made flexible cables. For your security, your equipment must be connected to an electrical outlet with grounding connection protection. Since the plug is used to disconnect the device, the operating electrical outlet must be in an easily accessible place.
  • Page 8: System Description

    SYSTEM DESCRIPTION Applications Arthur Holm’s DB2Share is a motorised retractable communication solution that creates minimum impact on the furniture’s design. It is easy to integrate, intuitive to use (one simple operation sensor located on top of the monitor) and almost invisible when not in operation (no cover plate, neatly streamlined into the furniture).
  • Page 9 SYSTEM DESCRIPTION Model AH17DB2Share HDCP compliant vertically retractable aluminium 17,3" Full HD monitor with 20 degrees of adjustable inclination. The monitor allows its installation to be flush with the desk when the monitor is in recessed position. A motorised retractable HDMI cable rises as an extension of the monitor.
  • Page 10 SYSTEM DESCRIPTION Box Contents Before the installation of your monitor, please check the contents of the shipping box, it must contain the following items: • Monitor • Power cord • Power supply 100-240Vac, 50-60Hz. Output 12V • User Manual Important note: This device can only work with the power supply included in the shipping box.
  • Page 11: Controls

    CONTROLS Remote control POWER Switch ON/OFF the monitor MENU Activates the OSD menu on screen Cursor control up on the OSD menu DOWN Cursor control down on the OSD menu LEFT Cursor control left on the OSD menu RIGHT Cursor control right on the OSD menu Selects the function on the OSD menu.
  • Page 12 CONTROLS IR sensor The IR sensor is located on the lower side of the screen. Monitor movement controls 1. Open / Close / Tilt button Up and Down control movements button. When the monitor is up, permanent press this button to make the monitor tilt up and down in a cycle.
  • Page 13: Osd Menu

    OSD MENU Accessing the menu system • With the OSD off, push the MENU button to activate the main OSD menu. • Press the UP and DOWN buttons to move from one function to another. Please refer to the following sections below to view a complete list of all the functions available for the monitor.
  • Page 14 OSD MENU Picture Noise Reduction: Adjusts the image noise filter ∙ Off ∙ Low ∙ Medium ∙ High ∙ Default Screen: (Only for analogue signals) ∙ Auto Adjust ∙ Horizontal Position ∙ Vertical Position ∙ Size ∙ Phase Backlight: Adjusts the backlight screen level Colour Range: Adjusts the colour range ∙...
  • Page 15 OSD MENU Option Language: OSD language selection Restore Factory Default: Adjusts the parameters to the initial factory parameters Blending: OSD window transparency ∙ Low ∙ Medium ∙ High ∙ Off OSD Duration: Adjusts the time that the OSD menu window remains on screen Software Update (USB): Used for firmware upgrade mirror Mirror:...
  • Page 16: Input Connectors

    INPUT CONNECTORS Monitor input connectors 12V D.C.: Power supply input connector. XLR-4 connector. - 1,2: Ground - 3,4: 12Vdc GPI: Monitor external contact close control. SubD9 female. 1 . GPI1 + 2. GPI1 – 3. GPI2 + 4. GPI2 – 5.
  • Page 17 INPUT CONNECTORS DynamicShare connectors HDMI LOOP OUT: Connect a HDMI cable to the next HDMI LOOP IN monitor in order to create a daisy chain loop installation. HDMI LOOP IN: Connect a HDMI cable from the previous HDMI LOOP OUT monitor, in order to create a daisy chain loop installation.
  • Page 18: Dynamicshare

    DYNAMICSHARE DynamicShare is equivalent to multiple HDMI selectors connected to multiple cascade HDMI distribution amplifiers in a daisy chain topology, allowing the user to display local sources privately, without affecting the other users in the loop. DynamicShare HDMI connection: The HDMI loop daisy chain connection allows sharing a local signal to all monitors.
  • Page 19: Dynamicshare Installation

    DYNAMICSHARE INSTALLATION One of the units is set-up as the MASTER unit. By connecting through a web browser, the use can access the internal web configuration. The factory IP address is 192.168.0.125. In AHnet control, please click on REBUILD LOOP. All the units should appear on the device list. The MASTER unit will assign a SHARE ID number to externally control the system.
  • Page 20 DYNAMICSHARE INSTALLATION Every time that the share system is initiated, the MASTER unit checks the HDMI loop. It takes about 3 minutes to complete the check-up. During this process, the MASTER unit checks the loop's is properly working. When the MASTER unit is checking the loop, the LEDs indicators of all units are flashing.
  • Page 21: Ahnet Protocol

    AHNET PROTOCOL Communications protocol COMMUNICATION RS422 CONNECTION RJ45 WIRING CAT-5 Speed and configuration BAUD RATE 38400 DATA BITS PARITY NONE STOP BITS Wiring Diagram 1. Data TX + 2. Data TX – 3. Data RX + 4. NC 5. NC 6 .Data RX –...
  • Page 22 AHNET PROTOCOL AHnet protocol Using 5 bytes communication: BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE BYTE 3 VALUE 1 BYTE 4 VALUE 2 Monitor AHnet control Use the AHnet RJ45 connector on the monitor IN and OUT connectors to create a RS422 BUS and send AHnet commands to the monitors.
  • Page 23 AHNET PROTOCOL Commands COMMAND DESCRIPTION RESPONSE FA XX 01 01 00 SCREEN UP FB XX 01 01 00 FA XX 01 00 00 SCREEN DOWN FB XX 01 00 00 FA XX 02 01 00 SCREEN ON FB XX 02 01 00 FA XX 02 00 00 SCREEN OFF FB XX 02 00 00...
  • Page 24 AHNET PROTOCOL Picture Commands COMMAND DESCRIPTION RESPONSE FA XX 15 00 00 ASK FOR BACKLIGHT LEVEL FB XX 15 00 ZZ FA XX 16 00 00 ASK FOR CONTRAST LEVEL FB XX 16 00 ZZ FA XX 17 00 00 ASK FOR BRIGHTNESS LEVEL FB XX 17 00 ZZ Number of the monitor address...
  • Page 25: External Share Control System

    EXTERNAL SHARE CONTROL SYSTEM Connect to the RS422 MASTER input unit to externally control the Share system using AHnet commands. Use the SHARE ID number assigned by the MASTER during the REBU ILDING process to send the commands to the monitor. Use the next connector on the MASTER unit to send the AHnet MASTER control commands.
  • Page 26 EXTERNAL SHARE CONTROL SYSTEM AHnet protocol Using 5 bytes communication: BYTE 0 START BYTE BYTE 1 ADDRESS BYTE BYTE 2 COMMAND BYTE BYTE 3 VALUE 1 BYTE 4 VALUE 2 AHnet commands COMMAND DESCRIPTION RESPONSE FA XX 05 00 00 VIEW LOOP FB XX 05 00 00 FA XX 05 01 00...
  • Page 27 EXTERNAL SHARE CONTROL SYSTEM AHnet commands Use the next parameters to send the WEB API commands to the system: IP factory stand-alone device 192.168.0.125 Command structure: http://<MasterIP>/ahnet/cmd/<AHNet command> For example, to SHARE HDMI1 signal from the MASTER monitor: http://192.168.0.125/ahnet/cmd/FA/00/05/0B/00...
  • Page 28: Information On Disposal

    INFORMATION ON DISPOSAL FOR USERS OF WASTE ELECTRICAL & ELECTRONIC EQUIPMENT This symbol on the products and/or accompanying documents means that used electrical and electronic products should not be mixed with general household waste. For proper treatment, recovery and recycling, please take these products to the designated collection points, where they will be accepted on a free of charge basis.
  • Page 29: Warranty Terms And Conditions

    WARRANTY TERMS AND CONDITIONS Albiral Display Solutions warrants this product against manufacturing defects and workmanship for a period of five (5) years from the date of purchase, subject to the conditions below. Mechanical parts: The engine and the product’s mechanical parts are warranted against manufacturing defects and workmanship for a period of five (5) years from the date of purchase.
  • Page 30 If you have any doubts concerning the terms of this warranty, please contact: business@albiral.com +34 938 502 376 Copyright © Dec. 2019. All rights reserved Albiral Display Solutions SL. Registered trademarks: Albiral, Arthur Holm, Pixtron Broadcast...
  • Page 32 Patents P27178ITEP P27178RUPC MU17180ES00 P27178USPC MU17301ES00 P27284DEEP MU17322ES00 P27284EPPC MU17413ES00 P27284ESEP MU17445ES00 P27284GBEP MU17854ES00 P27284RUPC MU17868DEPC P27284USPC MU17868RUPC P27715ESEP P24821DEEP P28089DEEP P24821ESEP P28089ESEP P24821GBEP Fàtima 25, Sant Hipòlit de Voltregà P28089ITEP P24821USPC 08512 Barcelona – Spain P28089USPC P27178DEEP tel: +34 93 850 23 76 / 23 83 P28090EP00 P27178EPDV01 fax: +34 93 850 25 50 / 23 72...

Table of Contents