Changing Cycles; Delayed Start Setup (Opl Only); Delayed Start (Opl Only); Overflow Mode - ALLIANCE HWNNE2HP115CW01 Original Instructions Manual

Topload washer
Table of Contents

Advertisement

Washer Operation

Changing Cycles

Cycles and wash temperature can be changed before the first fill
is complete. After the first fill, all key presses are ignored.
Selecting a higher priced cycle/wash temperature or modifier will
pause the first fill step, and INSERT COINS/CARD LED will
flash one (1) second on and one (1) second off until the vend
price has been satisfied. After the vend price has been satisfied,
the cycle will continue with the new selections. If the vend price
is not satisfied within one (1) minute, the washer control will go
back to the previously set cycle/wash temperature and modifier.

Delayed Start Setup (OPL Only)

Delayed Start Setup Mode is entered by holding any key except
for the START key for 5 seconds while in Start Mode. To prevent
changing the selected cycle and options, the user should press
and hold one of the actively selected keys.
The lid must be closed in order to enter this mode.
This mode is only manually accessible if the Delayed Start Mode
(Enable/Disable) parameter is programmed to Enabled. While in
the Delayed Start Setup Mode, pressing the DELICATES (∧) or
the COLD (∨) keypads will alter the number of hours the cycle is
delayed up to a maximum of 72 hours. The time will loop around
when the maximum or minimum value is reached. The display
will show XX HrS while modifying time or 01 Hr if 1 hour is
set and this display will toggle 1 second on and 1 second off.
If the lid is opened while trying to program the delayed start time,
the control will exit this mode and go back to Start Mode.

Delayed Start (OPL Only)

Delayed Start is entered by pressing the Start keypad while in
Delay Start Setup Mode. This mode is only manually accessible
if the Delayed Start Mode (Enable/Disable) parameter is pro-
grammed to Enabled. The OPL Delay Start programming param-
eter can be programmed through IrDA and Network commands.
The display will show XX HrS toggled with dELAy every 1 sec-
ond while counting down the hours. The display will show XX
Nin toggled with dELAy every 1 second once the time is 1 hour
or less (would transition from 02 HrS to 60 Nin). The display
will count down one hour or minute at a time showing a leading
zero for one digit numbers.
Once the countdown time has expired the cycle will begin. Cycle
selection related LEDs will be lit while in this mode.
This mode can be exited by pressing the Back keypad which will
then place the control into Start Mode.
If the lid is opened at any point while in this mode, Delayed Start
Mode will be exited and the control will enter Start Mode.
©
Copyright, Alliance Laundry Systems LLC -
DO NOT COPY or TRANSMIT

Overflow Mode

If the control receives input that the overflow level has been
reached the control will switch to Overflow Mode.
If Overflow Mode Display is disabled and the control will enter
Run Mode when it exits, the display will show the default Run
Mode display, otherwise in all other cases, the display will show
oFLo. If the lid is closed and the overflow level is no longer be-
ing met within five (5) minutes of first detecting the overflow, the
cycle will continue as normal and the control will go back to the
mode it was previously in. If the control continues to see an over-
flow error after five (5) minutes has been reached, the control
will enter Machine Error Mode with an Overflow Error.

Lockout Mode

If enabled in the Control Configuration, Lockout Mode is entered
to prevent the machine from being used except by a particular
user who has reserved the machine in advance. This mode is en-
tered when the current time (in Hours and Minutes) falls within
the time period set by the Lockout Mode Start Time Hour, Lock-
out Mode Start Time Minute, Lockout Duration, and when the
control is in Ready Mode. The display will show rES. User ac-
cess is ignored until Lockout Mode is exited. The control will be
able to communicate with the Network, IR, or the Serial Payment
System.
When entering the sequence of keypresses to exit Lockout Mode,
pressing the START keypad signals the end of the keypress se-
quence. As each keypad is pressed the corresponding LED is lit.
Anytime the START keypad is pressed the correct number of
keys entered is verified and if not equal to four (4) the keypad se-
quence will be reset, all LED's will be turned off, and keypresses
will be ignored for five (5) seconds while remaining in Lockout
Mode. In addition, if five (5) keypads are pressed before the
START keypad is pressed, the sequence will be reset, all LED's
will be turned off, and keypresses will be ignored for five (5) sec-
onds while remaining in Lockout Mode.
When the correct sequence of keypresses has been entered the
control will enter Ready Mode. If the network programs the dura-
tion to zero, Lockout Mode will be exited.

Shutdown Mode

Shutdown Mode is entered if a Low Power/Shutdown Option (1,
2, 3, or 4) becomes active with the Shutdown option enabled. To
become active, the Low Power/Shutdown Option must be ena-
bled in the Control Configuration and the current time, day-of-
week, date, month, and year must match the programmed start re-
quirements for the triggering Low Power/Shutdown Option.
If the control is in ready mode, drop-off mode, lockout mode, or
start mode when no vend has been entered, shutdown mode can
be entered. Shutdown Mode will automatically exit if the current
time, day-of-week, date, month, and year satisfy an exit condition
for the active Low Power/Shutdown Option. While in Shutdown
Mode, the control will show oFF and all LEDs will be turned off.
14
Part No. 204370ENR1

Hide quick links:

Advertisement

Table of Contents
loading