2.6 Cable Installation
2.6.4 Connecting the Control/Data Cables
This section provides detailed instructions for connecting the unit's control/data cables:
the HVPS-FPS cable, PN 0620-6672-0
the HVPS I/O cable, PN 0620-6682-0
the FPS I/O cable, PN 0620-6672-2

Figure 2-14 Control/Data Cable Connections on FPS Front Panel

Connect HVPS-FPS cable
(PN 0620-6672-0) to J102.
CV-6SLX User Manual
4
Secure the lugs on the ends of the HV cables to the feedthroughs,
as shown in Figure 2-12. Either cable can be connected to either
feedthrough, as polarity is not an issue.
Step
Action
1
Plug the male end of the HVPS-FPS cable (PN 0620-6672-0) into
connector J5 on the power module rear panel (see Figure 2-4).
2
Plug the female end of the HVPS-FPS cable for Gun #1 into
connector J102 on the FPS front panel (see Figure 2-14).
3
Plug the male end of the same HVPS I/O cable (PN 0620-6682-0)
into HVPS rear panel connector J4 (see Figure 2-4).
4
Plug the male end of the FPS I/O cable (PN 0620-6672-2) into
connector J101 on the FPS front panel (see Figure 2-14).
5
Make the I/O connections to the control system, as described in
section 2.6.5.
2-12
Section 2: Installation
Connect FPS I/O cable
(PN 0620-6672-2) to J101.
0101-8242-0, Rev. C