Figure 5-10 Aux Supply Low And External Control Fault Leds - ferrotec Temescal CV-6SLX User Manual

Table of Contents

Advertisement

5.3 Ishikawa Diagrams

Figure 5-10 Aux Supply Low and External Control Fault LEDs

Aux Supply Low LED
LED turns red when the nominal
+24 VDC control voltage drops
below +19.5 VDC
External Control Fault LED
LED lights red: (a) when fault
occurs in internal I/O switch
power, or (b) when fault occurs
in the external control circuit
powered by +24 VDC supplied
via J4 pin 6
5.3
Ishikawa Diagrams
Each of the following diagrams illustrates the troubleshooting logic that applies in the case of a
given fault condition. The diagrams, in order, are:
Ishikawa Diagram #1: No Input Power ......................................................................................... 5-7
Ishikawa Diagram #2: Interlock Fault ........................................................................................... 5-7
Ishikawa Diagram #3: No Beam After HV and Gun Are Switched ON ............................................... 5-8
Ishikawa Diagram #4: HV Output Unstable ................................................................................... 5-8
Ishikawa Diagram #7: Rail Undervoltage Fault ............................................................................ 5-10
Ishikawa Diagram #8: HV Overcurrent Fault ............................................................................... 5-10
Ishikawa Diagram #9: HV Overvoltage Fault ............................................................................... 5-11
Ishikawa Diagram #10: Setpoint Overvoltage Fault ........................................................................ 5-11
Ishikawa Diagram #11: Output Arcing Fault .................................................................................. 5-12
Ishikawa Diagram #12: Overtemperature Fault ............................................................................. 5-12
Ishikawa Diagram #13: Aux Power Supply Low Fault ..................................................................... 5-13
Ishikawa Diagram #14: External Control Fault ............................................................................... 5-13
Ishikawa Diagram #15: Filament Load Fault .................................................................................. 5-14
Ishikawa Diagram #17: Emission Current Unstable ........................................................................ 5-15
CV-6SLX User Manual
LED Lights Frequently ................................................. 5-9
5-6
Section 5: Troubleshooting
0101-8242-0, Rev. C

Advertisement

Table of Contents
loading

Table of Contents