Operation Of The Seed Dispenser - UNIA FENIX G Operating Manual

Seed drill
Table of Contents

Advertisement

After that, set the dosing roller according to "SETTINGS FOR FINE SEEDS".
Fig. 13.1
CAUTION!
In case of difficulties with setting the dose of fine seeds (e.g. rape in a dose smaller than 2.5kg/ha), we suggest
the following solution: while maintaining the above requirements, set the metering roller to twice the required
value, extend the small gear (red) from the big gear and mesh it with the other big gear wheel. In this way, you
should receive the required sowing rate, which should be confirmed by the sowing test. After sowing in this way,
you should go back to the previous setting of the gears, that is, the small wheel should be inserted into the large
one.
Caution:
After shifting the gear on the unit, change the setting to 2:1 in the controller.

3.3.4. Operation of the Seed Dispenser.

CAUTION!
The dispenser may only be used for metering with the seed material specified in the sowing chart. For sowing
other materials, it is absolutely necessary to make arrangements with the machine manufacturer.
We recommend that you learn thoroughly operation of the entire dispenser and air system after purchasing
any part of the dispenser or the entire air sowing system, and before its installation and use, especially its part,
where the purchased part will be installed.
Proper and efficient maintenance will extend the lifetime of the dispenser and it may be carried out by a
person, who has been trained to operate and maintain the unit.
Each dispenser has a logo and serial number (five digits) stamped on its housing.
The allowed speed of the dispenser shaft is n
NOTE!
1. It is forbidden to drive the dispenser shaft at a speed different than specified.
2. Decrease the sowing rate with the dispenser empty and cleaned or during sowing. Residues in the dispenser
will prevent proper setting of the metering roller, and in extreme cases, may cause damage to the dispenser.
3. Rotating the metering roller in the direction opposite to the driving direction is forbidden, since this may
cause damage to the dispenser.
FENIX G Operating manual
Fig. 13.2
=[120 RPM.]
max
- page 23 -
Fig.13.3