Master Protecting Controller Reds Configuration - Datalogic SC6000 Installation Manual

Reds redundancy system
Hide thumbs Also See for SC6000:
Table of Contents

Advertisement

11. Digital I/O Setting
Only one Controller (the Working or the Protecting) will have the OUT-6
On. This output is used to inform the Host about which is the Active
Controller:
NOTE
12. Operating Modes
13. Operating Modes
14. Operating Modes
This three parameters above are very important in order to avoid
Glitch and packs too short or too near not realistic as you can see in
the picture below.
NOTE
15. Send the configuration to the Working Controller: Send with Options + Environmental
Parameters.
16. Save the configuration on the PC.

2.7.2 Master Protecting Controller REDS configuration

Starting from the Default, complete the Protecting Controller configuration as follow:
1. Load the Configuration of the Working Controller from the PC.
2. Change only the parameter:
Master Protecting.
3. Send the configuration to the Protecting Controller: Send with Options + Environmental
Parameters.
Digital Output Lines Setting
OUT-6 On = Controller is Active
OUT-6 Off = Controller is in Stand By
Minimum Distance Between Packs (mm) = 200.
Minimum Pack Length (mm) = 200.
Window Dimension (mm) = 200.
Glitch or pack too short
200 mm
Redundancy Parameters
Output 6
Use = Redundancy.
Topology Redundancy =