2.7 REDS PARAMETERS CONFIGURATION

2.7.1 Master Working Controller REDS configuration

After the Net and Scanner setting, complete the Working configuration as follow:
1. Redundancy Parameters
2. Redundancy Parameters
3. Data Communication settings
Active = insert the IP address of your Master Working.
4. Data Communication settings
Stand-by = insert the IP address of your Master Protecting.
NOTE
5. Data Communication settings
= insert the IP netmask.
6. If it is necessary set parameter: Data Communication settings
Line Parameters
7. If it is necessary set parameter: Data Communication settings
Line Parameters
8. If it is necessary set parameter: Data Communication settings
Line Parameters
For the use of WebSentinel it's necessary to set the parameters below:
9. Data Communication settings
Enable = checked.
10. Data Communication settings
Status = checked.
NOTE
Reds Functionality = checked.
Topology Redundancy = Master Working.
The IP_address Active must be different to the IP_address Stand-by.
The two IP_address must be on the same sub-net.
IP_ gateway = insert the IP gateway.
IP_ dns1 = insert the IP dns1.
IP_ dns2 = insert the IP dns2.
When an UserSocket# is used with WebSentinel, Data Tx must be
unchecked.
Built-in Ethernet
Built-in Ethernet
Built-in Ethernet
Built-in Ethernet
Built-in Ethernet
Line Parameters
Line Parameters
Line Parameters
Built-in Ethernet
Built-in Ethernet
Built-in Ethernet
Services
SentinelClient
Services
UserSocket#3
IP_address
IP_address
IP_netmask