Intec ColorCut FB550 Series Installation & Setup Manual page 36

Dual tool, flatbed digital die-cutters
Table of Contents

Advertisement

3.5.2 Calibration of the Sensor Offset to the Cutting Blade
The Sensor Offset Calibration value, is stor ed in your ColorCut Pr o application and so
the calibration is perfomed by ColorCut Pr o. To continue the calibration pr ocess you
will need to launch the ColorCut Pro application and open the [SETTINGS] dialogue box
as shown below.
8.
Open
ColorCut
Windows
Open the Windows [START]
menu
and select ColorCut
Pro from the Programs/Intec
folder.
The ColorCut Pro splash
screen will briefly appea ,
then the main ColorCut Pro
application will be displayed.
9.
The "Vision Sensor Offset"
setting provides the
ability to calibrate the sensor offset
automatically by using the Auto-Find
feature
3
AND shows the current
2
setting
(which can be manually
adjusted if you prefer).
10
. Click the [ AutoFind] button
to start the automatic sensor
offset
calibration.
ColorCut
the Pen Calibration Tool to
repeatedly draw a box with a
thick frame
the box, it will then scan the
frame and automatically enter
the values into your Sensor
Offset X and Y settings. It will
display a message when the
process is complete.
You can now close this window, the calibration for ColorCut Pro is now complete.
Intec Printing Solutions - Manual for ColorCut flat bed series FB550 ..................................................................................... Page No: 36
Pro
from
menu
1
The
FB550 will use
. After drawing
B
C
D

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Colorcut fb750 seriesColorcut fb1150 series

Table of Contents