Connecting Power And Start-Up; Initial Access To X2-3200G - ProfiTap X2-3200G Product Manual

Packet broker
Hide thumbs Also See for X2-3200G:
Table of Contents

Advertisement

3. CONNECTING POWER AND START-UP

After ensuring all the necessary precautions have been taken during installation, the
unit can be powered on. The system does not have a main switch: it powers up if
one of the redundant power supplies is being connected to the main power.
The use of both power supplies is recommended to achieve a maximum fail-safe
operation at all times.
The power supply modules are hot swappable: they can be exchanged or new mod-
ules can be added at all times under power, but data loss during the exchange must
be taken into account.
The
X2-3200G
is equipped with status and activity LEDs. For more details on status
LEDs color and coding, see chapter

4. INITIAL ACCESS TO X2-3200G

The first-time access to the system can only be done through the serial connection,
using the supplied cable and adapters. Using any terminal software, use the follow-
ing connection settings must be used: 115200 baud rate, 8 bit, no parity, 1 bit stop.
Login, using the following credentials:
Username: profitap
Password: profitap
Follow the prompt to create an administrator account. After creating the new admin
user, the session will close. The factory default user (profitap) remains active for
direct connections to the unit's serial management port.
2.5 LED Functionality
7
chapter.

Advertisement

Table of Contents
loading

Table of Contents