Using a Dust Bag system (plastic bag insert) (Fig. 9)
Having opened the system, remove the plastic bag's edge
carefully from the container's rim. Close the bag's opening
and take it out of the container.
Put a new bag into the container. Take care that it fits the
bottom and the walls. Pull the bag's edge over the container's
rim and smooth it down.
Dust Class "L"
Machines of this category of application can be used without
a dust bag. In this case please make sure that the removal of
the dust takes place in a special area and use a respiratory
protection mask.

Technical data

Model
IV 022
IV 022 EL
A [mm]
1,210
B [mm]
630
C [mm]
1,500
Weight [kg]
180
Specifications
Voltage [V]
Frequency [Hz]
IP protection Class
Insulation class
Dust class
Rated Power [kW]
Suction power [W]
3
Airflow [m
/h]
Vacuum [mbar]
Sound pressure level at 1.5 m
[DBA] ISO3744
Container capacity [L]
Main filter area
Cable length [m]
Inlet [mm]
Length x Width x Height [mm] 1,210x630x1,500 1,210x630x1,500
Weight [kg]
32401105(2)2006-10 A
32401105(3)2006-12 A
IV 040
IV 040 EL S
1,210
1,210
1,210
630
630
630
1,500
1,500
1,500
187
197
205
IV 022
IV 040
400V 3N AC
400V 3N AC
50/60 Hz
50/60 Hz
50/60
50/60
55
55
F
F
L, M, H
L, M, H
3.5
4.9
267
588
240
330
215
215
67.9
73.2
100
100
17,600
17,600
9.5
9.5
50
50
180
197
INSTRUCTIONS FOR USE

Maintenance

Foreword

The operator must disassemble, clean and service the
vacuum cleaner only when these procedures cannot cause
damage to the personnel in charge for the maintenance and
other people.
Precautions include cleaning before disassembly, forced
ventilation in the room where the vacuum cleaner is
disassembled, cleaning of the place where maintenance is
performed and protective clothing.
Vacuum cleaners for dust class H and M needs to be cleaned
in their exterior parts. Collect the dust or seal it before the
vacuum cleaner is taken out of the danger zone. All vacuum
cleaner components are to be considered contaminated
when they are taken out of the danger zone, so avoid to
shatter the dust.
ATTENTION!
All maintenance and cleaning operations must
be carried out when the vacuum is off and
disconnected from the mains socket.
The suction unit needs no particular maintenance or
lubrication.
Remember, however, that correct use and servicing are
essential if the safety and efficiency of the vacuum are to be
guaranteed.
To ensure regular and constant operation and to prevent the
warranty from becoming void, only ever use genuine
Nilfisk-Advance A/S spare parts when replacements are
needed.

Checks and inspections on start-up

The customer should proceed with the following inspections
to ensure that the vacuum has not been damaged during
transportation.

Before starting

Check that the mains voltage value corresponds to that for
which the machine is preset.
Check that all warning and danger plates are affixed and
legible.
Check that all protections are installed and efficient.
During maintenance or repair procedure, it is necessary to
dispose of all the contaminated objects that cannot be
properly cleaned.
These objects must be disposed of in waterproof bags,
according to the law in force.
11