Vacuum cleaner used for absestos

On vacuum cleaners with an accessory for the removal of
asbestos dust the ABS container insert or the protective bag
system must always be used. An exhaust connection must be
attached to the side outlet, through which air can be
exhausted from the working area. The exhaust hose can be
directed to the open air or to a ventilation system installed in
the working area.
The exhaust connection for the air outlet must be fitted with a
70 mm PUR H hose with a length of < 5 m. This hose is
contained in the Asbestos Kit, which can be supplied for the
machine. As already mentioned, the hose can either be
exhausted directly to the open air or to a ventilation system
installed in the working area.
NOTE
If the machine is to be used for the suction
removal of asbestos dust, either the ABS
container or the protective bag system must be
used.
ABS container
32400059
Protective bags
03034000
The disposal of the dust container must be entrusted to
qualified personnel only, according to the instructions in the
User Manual.
After using the vacuum cleaner for asbestos according to the
TRGS 519, the vacuum cleaner cannot be used in the so
called "white environment". The only allowed exception is that
the vacuum cleaner has been previously decontaminated by
a qualified technician according to TRGS 519 N.2.7
regulation. (Decontamination includes: outer carter, interior
components, such as cooling air ducts, electrical components
compartments and the components themselves, etc.). The
technician must fill in documents to certify that the
decontamination procedure has been performed.
When transporting the machine you must make sure that it
has been cleaned in accordance with the regulations
stipulated in TRGS 519. The machine can also be transported
in a sealed container from which no contaminated dust can
escape.
The filters must be replaced only in proper places (for
example in decontamination stations).
The filter replacement must be performed by qualified
personnel only, according to the instructions in the User
Manual. The filters must be replaced only in proper places (for
example in decontamination stations).
32401105(2)2006-10 A
32401105(3)2006-12 A
INSTRUCTIONS FOR USE
Filter replacement
Make sure that the filter is covered with a suitable plastic bag
before it is removed.
Remove the suction pipe "1" from the lower connection.
If the filter assembly is very heavy, remove the upper cover
and lift the assembly from the machine using the two handles
provided. Unscrew the clamp, which attaches the filter to the
basket, and lift the basket from the filter.
Rotate the filter and reveal the plastic strip "2".
Place the filter in a plastic bag, cut the plastic strip and free
the basket from the filter.
Seal the plastic bag containing the filter.
WARNING!
The collected dust must be transported into
air-tight container and cannot be transferred
into another container. Disposal of waste
material containing asbestos must be
performed according to the laws in force.
Maintenance and, if necessary, repairs and
checks on industrial vacuum cleaners must be
performed once per year by a qualified
technician (qualified according to TRGS 519
no. 5.4.3, Par. 2 regulation). Check results must
be shown upon request.
If the filter is soiled by poisonous or otherwise dangerous dust
do not throw it away. Hand it to an authority, which is
authorised for the disposal of this type of waste.
Take particular care when replacing the main filter or the
complete filter and wear a P3-type mask.
ATTENTION!
The replacement of the filter is an important
procedure.
The filter must be replaced by another filter
with the same characteristics and the same
filter surface and category. If these rules are
not followed the vacuum cleaner may not
function correctly.
Obtain a filter with the same characteristics as the old filter
and proceed as follows: (Fig. 17).
Fit the filter lock and the sealing ring of the old filter to the new
filter.
Insert the cage "4" and secure the filter using the plastic strip
"2" on the bottom of the filter.
Fit the filter rod in the filter shaking system and tighten the
screw.
Fit the upper cover on the filter unit.
Re-insert the filter unit into the machine.
Re-attach the suction pipe "1" in its original position.
Fix the clamp, which holds the filter unit on the machine.