4.11

Activate / deactivate automatic table feed

The feed drives consist of a universal helical gear and an inverter motor in each axis. The feed
force is 1600 N with a continuously adjustable feed from 0.05 metres per minute to 0.45 metres
per minute. The rapid traverse speed is 0.78 metres per minute.

4.11.1 Switching the X - Y - Z axis feed on

ATTENTION!
Loosen clamping lever on the cross table.
Loosen clamping lever on the milling head.
Set feed rate to "0".
Switch on drive motor for the feed.
Set the direction lever X, Z or Y in the desired
feed direction and engage.
Slowly increase the feed rate.

4.11.2 Switching the X - Y - Z axis feed off

Set the feed direction lever to the neutral position.
Switch off drive motor for the feed.
Set feed rate to "0".
4.11.3 X - Y - Z axis rapid traverse
Loosen the clamping lever.
Switch on drive motor for the feed.
Set the direction lever in the desired direction.
Operate the push-button on the control panel.
GB
MZ4S
42
Translation of the original instructions
+Z
+Y
+X
0
0
Version 1.0.4 - 2020-07-31