14 ADDITIONAL TECHNICAL INFORMATION
14.1 MAXIMUM WORKING PRESSURE CHART
Maximum working
pressure (psi)
EVMSU1
232
2-18
375
20-29
Maximum working
pressure (psi)
EVMSU10
232
1-10
11-16
375
Maximum working
pressure (psi)
EVMU32
232
1-4
5-8
360
9-10
430
15 POSITIONING OF HOLES FOR FASTENING DOWN
Pump
D
model
mm
EVMS1
EVMS3
EVMS5
12
EVMS10
EVMS15
EVMS20
EVM32
EVM45
14
EVM64
Pump model
D
in
EVMS1
EVMS3
EVMS5
15/32
EVMS10
EVMS15
EVMS20
EVM32
EVM45
9/16
EVM64
EBARA
www.pumpsebara.com
Pump model
EVMSU3
EVMSU5
2-15
2-12
16-23
13-19
Pump model
EVMSU15
EVMSU20
1-7
1-6
8-12
8-10
Pump model
EVMU45
EVMU64
1-3
1-3
4-7
4
A
B
mm
mm
100
180
130
215
170
240
190
266
A
B
in
in
3 15/16
7 3/32
5 1/8
8 15/32
6 11/16
9 7/16
7 15/32
10 15/32
Pumps Americas Corporation
15.1 WARNINGS FOR CORRECT OPERATION OF EVMU
AND EVMSU PUMPS (FIG. 1 - FIG. 2)
FIG. 1
a) Adequate immersion;
b) Positive slope;
c) Wide-radius bend
d) Pipework with independent supports;
e) Suction pipe diameter ≥ pump port diameter;
f) Reducing coupling for eccentric pipes.
FIG. 2
a) Insufficient immersion;
b) Negative slope, air pockets created:
c) Tight bend, pressure loss;
d) Pipe diameter < pump port diameter, pressure loss