Electro Cam PLUS PS-5000 Series Programming & Installation Manual page 74

Programmable limit switch
Table of Contents

Advertisement

DC Inputs:
EC-IDC5 (Standard)
EC-IDC032 (Slimline)
Input Voltage:
10-32 VDC
Input Current:
34 mA maximum (@32 VDC input)
Output Supply
Voltage:
4.5 VDC to 6 VDC
5 VDC nominal
Output Supply
Current:
18 mA DC maximum @ 5 VDC
Turn On Time:
5 ms maximum
Turn Off Time:
5 ms maximum
Dropout Voltage:
2 VDC maximum
Pickup Voltage:
3 VDC minimum
Operating Temp:
-30 to +70°C (-22° to +158°F)
AC Inputs:
EC-IAC5 (Standard)
EC-IAC120 (Slimline)
Input Voltage:
90-140 VAC rms
Input Current:
11 mA AC rms maximum
(@140 VAC rms input)
Output Supply
Voltage:
4.5 VDC to 6 VDC
5 VDC nominal
Output Supply
Current:
16 mA DC maximum @ 5 VDC
100 μA DC maximum @ 30 VDC
Off State Leakage:
Output Voltage Drop: 0.4 VDC @ 50 mA DC
Output Current:
50 mA DC maximum
Turn On Time:
20 ms typical
Turn Off Time:
20 ms typical
Input Allowed
for No Output:
45 VAC rms,
3 mA AC rms maximum
Operating Temp:
-30 to +70°C (-22° to +158°F)
AC Inputs:
EC-IAC5A (Standard)
EC-IAC240 (Slimline)
Input Voltage:
180-280 VAC rms
Input Current:
5 mA AC rms maximum
(@280 VAC rms input)
Output Supply
Voltage:
4.5 VDC to 6 VDC
5 VDC nominal
Output Supply
Current:
16 mA DC maximum @ 5 VDC
100 μA maximum @ 30 VDC
Off State Leakage:
Output Voltage Drop: 0.4 VDC @ 50 mA DC
Output Current:
50 mA DC maximum
Turn On Time:
20 ms typical
Turn Off Time:
20 ms typical
Input Allowed
for No Output:
45 VAC rms,
1 mA AC rms maximum
Operating Temp:
-30 to +70°C (-22° to +158°F)
Input Module Specifications
Appendix
A-22

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents