Electro Cam PLUS PS-5000 Series Programming & Installation Manual page 30

Programmable limit switch
Table of Contents

Advertisement

The 5000 Series of controls have three levels of programming
access. Entry into these levels of programming is
accomplished through dedicated hardware inputs and/or
programmable enable codes entered through the keyboard.
Master Level—Accesses all programmable features. In
addition to all setpoints and functions, the Master Level also
establishes the keyboard entry codes for the "Setup" and
"Operator" access levels. Master Level programming also
determines which outputs are accessible to the operator.
NOTE: On units prior to date code 9740, operator access
was limited to setpoints and timed output values, unless
equipped with the Expanded Operator Access (-E) option.
Setup Level—Accesses all output setpoints and the
functions listed on the keyboard. These are control aspects
that may need occasional adjustment, but go beyond normal
operator responsibilities.
Operator Level—Functions available as specified in Master
Level programming. The operator is allowed to change the
following settings for output channels designated in FCN 6:
• Setpoints
• Timeouts
• Motion Detection Settings
Logic Terminal Strip
LOGIC COMMON
PROGRAM SELECT 1
PROGRAM SELECT 2
PROGRAM SELECT 3
MASTER PROGRAM ENABLE
OUTPUT GROUP ENABLE 1
MOTION DETECTION OUTPUT
OPERATOR PROGRAM ENABLE
+12VDC OUT - 150 mA MAX
Keyboard Enable Codes for Setup and Operator Access
Programming Access Levels
Levels of Programming Access
• Offset
• Active Program Number
• Speed Comp Settings
Hardware Program Enable Circuits
1
2
3
4
5
6
7
8
9
10
Either the Setup or Operator programming levels can be accessed by
entering the corresponding program enable code through the keyboard.
These codes can be 1, 2, 3, or 4 digit numbers and are established
during Master Level programming.
To Enter a program enable code number press:
FCN
The PE codE message will disappear when a valid enable code is
entered.
The level of access gained depends upon which code number is
entered.
Programming access will time-out approximately 5 minutes after the
last keystroke. To cancel access before the 5 minute time-out press:
FCN
4-1 Programming, Standard Features
The table below details which functions and set points can
be changed at the three levels of programming access. It
also indicates if the programming access levels can be
accessed by hardware input and/or keyboard enable code.
FEATURE
Enable Method
Output Set Points
Output Time Out Values All
Motion Set Points
Offset
Active Program
Speed Compensation
Direction of Rotation
Scale Factor
Set Up Enable Code
Operator Enable Code
Time Base Selection
Motion ANDed Outputs
Select Operator Outputs Yes
Output Enable Modes
OPTIONAL FEATURES:
Lead/Trail Speed Comp
Communication Setup
Analog Setup
Master Programming is enabled when terminal 6 is connected
to terminal 1 or 2. The Master Level can only be accessed by
energizing this input.
Operator Programming is enabled when terminal 9 is connected
to terminal 1 or 2. The Operator Level can also be accessed
through a keyboard enable code.
0
ENT
1st digit
2nd digit
0
ENT
CLR/CLE
MASTER
SET UP
OPERATOR
hardware
code
hardware / code
All
All
Selected
All
Selected
Yes
Yes
Selected
Yes
Yes
Selected
Yes
Yes
Selected
Yes
Yes
Selected
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
No
No
No
No
Yes
No
No
Yes
No
No
Yes
No
No
Yes
Yes
Selected
3rd digit
4th digit
ENT
ENT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents