Electro Cam PLUS PS-5000 Series Programming & Installation Manual page 71

Programmable limit switch
Table of Contents

Advertisement

ENCODER(S)
Operating Temp:
0° to 50°C (32° to 122°F)
Storage Temp:
-40° to 50°C (-40° to 122°F)
Operating Humidity:
95% Relative non-condensing
NEMA Rating:
NEMA 12 (PS-4256, 4257)
NEMA 4X (PS-4456, 4457)
Max Cable Length:
1000 Ft.
Enclosure Size:
6"W x 6"L x 4.25"H
Mounting Holes (4):
5/16" Diameter
Weight:
9 Lbs.
Shaft Diameter:
.75" (double ended) with
Woodruff keyway #606
Maximum RPM:
1000 RPM (PS-4256, 4456)
2000 RPM (PS-4257, 4457)
Resolution:
8 Bits (256 increments)
Accuracy:
+/-0.7°
RESOLVER(S)
Operating Temp:
-40° to 125°C (-40° to 257°F)
Storage Temp:
-40° to 125°C (-40° to 257°F)
Operating Humidity:
95% Relative non-condensing
NEMA Rating:
NEMA 4
NEMA 4X
Maximum RPM:
3000 RPM
Max Cable Length:
1000 Ft.
Type:
Single Turn - Brushless
Resolution (all):
12 Bits (4096 increments)
Linearity (standard):
+/-20 arc minutes (resolver only)
(+/-30 arc minutes combined with
R/D converter in controller)
Linearity (specials):
+/-3 to +/-10 arc minutes
(resolver only)
(+/-7 to +/-14 arc minutes
combined with R/D converter
in controller)
Note: A resolver's linearity errors are repeatable at all
positions of its 360 degree rotation. Therefore, once
appropriate setpoints are established, machine performance
is consistent every cycle.
Transducer Specifications