Cable For Stainless Steel Resolver - Electro Cam PLUS PS-5000 Series Programming & Installation Manual

Programmable limit switch
Table of Contents

Advertisement

With Rear Connector (shown):
PS-5262-11-ADR
With Side Connector:
PS-5262-11-ADS
Cable:
PS-5300-01-XXX where "XXX" is length in feet.
Cable for Stainless Steel Resolver with Terminal Strip Connections
Connector - Controller End
PT# PS-5300-01-TER
(Weidmuller # BLA7 12822.6)
Green
Black
Red
Black
White
Black
Shield
Shielding Note: This type of resolver cable will have a spade lug connected to the shield at the resolver end. The lug should
be attached to the grounding stud on the cover plate of the resolver. In some installations, it may be advisable to disconnect
the lug to prevent ground loops through the cable shield. Consult Electro Cam if electrical noise problems are suspected.
Horizontal Mount
PS-5262-11-CTG (with right connector)
PS-5262-11-CTL (with left connector)
Vertical Mount (Shaft Up)
PS-5262-11-CTG-V (with right connector)
PS-5262-11-CTL-V (with left connector)
Cable: PS-5300-02-XXX where "XXX" is length in feet.
Resolver Wiring and Dimensions
Flange Mount Resolver - 5/8" Shaft
STAINLESS STEEL RESOLVER
PT# PS-5300-02-XXX (XXX = Length in Feet)
Cable Type:
3 individually shielded pairs, 22 guage
Shield
(see note below)
Stainless Steel Foot Mount Resolver - 5/8" Shaft
For horizontal applications
3-15 Wiring
White
Black
Black
Red
Black
Green
Shield
.625/
.624" dia.
15.88/
15.85 mm
Connector Inside Resolver
(cable is stripped and tinned at
both ends)
WHITE
BLK (P/W) WHITE
BLK (P/W) RED
RED
BLK (P/W) GREEN
GREEN