Master Level Programming, Standard Controls: FCN 6 & FCN 7
FCN 6 - Operator Access
(Master Program Enable Input MUST be energized)
This function selects which features can be adjusted at
the Operator access level. Step through them one at a
time, and select On or Off according to whether or not
the Operator should be able to adjust them.
Functions that are not Channel-Specific:
Sd—Speed Detection (FCN 1, Motion Setpoints and Analog
Parameters if control has the "-A" option)
on
Operator can adjust FCN 1 values
oFF Operator cannot adjust FCN 1 values
oF—Offset (FCN 2)
on
Operator can adjust offset values
oFF Operator cannot adjust offset values
AP—Active Program (FCN 3)
on
Operator can change program number
oFF Operator cannot change program number
Functions that are Channel-Specific:
The following functions—"SP," "Sc," and "to"—will be
adjustable only for those channels turned "on" through
"Output Channel Selection."
Output Channel Selection
on
Operator can adjust values in this channel
oFF Operator cannot adjust values in this channel
SP—Setpoints
on
Operator can adjust setpoints
oFF Operator cannot adjust setpoints
Sc—Speed Compensation (FCN 4)
on
Operator can adjust speed comp values
oFF Operator cannot adjust comp values
(Encoder-based controls with the "-E" option have
Negative Speed Compensation capabilities, page 4-9.)
to—Timed Outputs (FCN 5)
on
Operator can adjust timed outputs
oFF Operator cannot adjust timed outputs
NOTE: On units manufactured prior to date code 9740,
operator access was limited to setpoints and timed
ouput values, unless equipped with the Expanded
Operator Access (-E) option.
4-7 Programming, Standard Features
Setting Output Channel Access
1st
If FCN 6
Output
not shown press:
Channel
selected
FCN
6
ENT
2nd
Press CHN key
3rd
to select Output
Channel
Setting Operator Accessible Functions
1st
If FCN 6
SP, Sd, oF,
not shown press:
AP, Sc, or to
selected
FCN
6
ENT
2nd
Press CHN key
3rd
to select function
Operator Enable status
shown for selected
output channel
Press PULSE key to toggle
Enable Status on and off
Operator Enable status
shown for selected
function
Press PULSE key to toggle
Enable Status on and off