Setup Level Programming, Standard Controls: FCN 1, FCN 2, FCN 3
If the hardware program select inputs are going to be used
to select programs (they can be driven from a PLC or
selector switch), it may be necessary to program the Program
bank (Pb) and Active Program (AP) from the keyboard.
Follow the instructions given below under "Hardware
Selection of Program Number."
Viewing or Changing Active Program Number from
Keyboard
Use the Program number (Pn) feature of FCN 3 to see the
active program number or select any program directly by
entering the corresponding number from 1-64. The
corresponding "Pb" and "AP" values will automatically be
calculated and selected. It will not be necessary to calculate
or program "Pb" or "AP", but they can be viewed to verify that
their values correspond to the selected program number.
Pn— Program number (1-64)
Pb— Program bank (1-8); 8 banks of 8 programs each
AP— Active Program (1-8); active program within bank
Example:
If Program number (Pn) 34 is selected, "Pb" will equal five
(5th bank of eight programs) and "AP" will equal two (2nd
program within this bank).
DO NOT enter values into "Pb" or "AP" if the keyboard
program selection is being used. Simply program "Pn" to the
desired program number from 1-64.
Hardware Selection of Program Number
The hardware program select inputs override the keyboard
programmed Active Program (AP) value when any one or
combination of the inputs is energized. When the hardware
inputs are used to select the Active Program (AP), insure
that "AP" is set equal to one.
The hardware select inputs only affect the current "AP"
value that is controlling the outputs. The "Pb" is not affected
by the select inputs and has to be changed from the
keyboard if more than eight programs are used.
To summarize, hardware select inputs can select which of
the eight programs in the current program bank is controlling
the outputs, but changing the program bank number must
be done through the keyboard by programming "Pb."
Note: Active Program and Program Bank can be changed
through the serial communication port also.
4-11 Programming, Standard Features
Viewing/Changing Program Number
1st
If FCN 3
Pn
not shown press:
Program
number
FCN
3
ENT
2nd
Press CHN key
3rd
to select Pn
Viewing/Changing the Active Program
1st
If FCN 3
AP
not shown press:
Active
Program
FCN
3
ENT
2nd
Press CHN key
3rd
to select AP
Viewing/Changing Program Banks
1st
If FCN 3
Pb
not shown press:
Program
bank
FCN
3
ENT
2nd
3rd
Press CHN key
to select Pb
Present Program
number shown
Press number keys followed by
ENT to change active Program
number. (1-64 are valid Program
numbers)
Present Active Program
number shown
Press 1
key followed by
ENT to change active Pro-
gram to 1.
Present Program Bank
number shown
Press number keys followed by
ENT to change Program Bank