11. Periodic Cleaning Guidance
1. Periodically clean the oil tank 2, 3 or 6 months depending on usage and contamination.
2. Periodically clean the sensor and filter footer 2, 3 or 6 months by:
Cover a sensor's vent before using the air sprayer for another.
Remove and clean the filter footer.

12. Troubleshooting

No.
1
2
Phenomena
No output
Signal interference
Reasons
Sensor's powering wire is
damaged
Overpowering has burnt the signal
cable and circuit board
Being tampered
Sensor was installed too far from
central hole of tank
Solutions
Check out on the sensor's
powering wire
Send to manufacturer
Check the seal again before
sending back to manufacturer
Install sensor as closest as
possible to the central hole of tank
(the common point of 02
diagonals)