Download Print this page

Advertisement

Quick Links

Manual for LoRaWAN
Sensors - Common parts
What is LoRaWAN?
Troubleshooting for LoRaWAN communication
Offline configuration for LoRaWAN sensors

Advertisement

loading

Summary of Contents for daviteq LoRaWAN

  • Page 1 Manual for LoRaWAN Sensors - Common parts What is LoRaWAN? Troubleshooting for LoRaWAN communication Offline configuration for LoRaWAN sensors...
  • Page 2 What is LoRaWAN?
  • Page 3 Troubleshooting for LoRaWAN communication This is the troubleshooting for the LoRaWAN sensor with FW versions listed below: Phenomena Reason Solutions The BLUE LED does not blink Insert the batteries in the Insert the battery in the correct when the battery is installed...
  • Page 4 The value of the sensor is 0 Lost connection with the sensor · Check sensor connection and sensor_type = 0xFF · Replace the module sensor RSSI is weak and often loses · Distance between Node · Configure Data rate = DR0 / data and Gateway is far or there are SF12...
  • Page 5 How to install driver 2. A modbus configuration cable 3. Tools to open the plastic housing of Lorawan sensors (L hex key or screwdriver) 2. Download and launch Daviteq modbus configuration software Click to the link below to download Daviteq modbus configuration software: https://filerun.daviteq.com/wl/?id=yDOjE5d6kqFlGNVVlMdFg19Aad6aw0Hs...
  • Page 6 - Connect the USB-A plug into the USB-A socket of the - Use the configuration cable (Item code: TTL-LRW-USB- 01). - Plug the cable connector into sensor's modbus configuration port. - Open the housing of the sensor. Step 2: On the configuration software, choose relevant Port (the USB port which is the cable plugged in) and set the BaudRate: 9600, Parity: none Step 3: Click “...
  • Page 7 Step 4: Import the configuration file for the sensor to the software: click menu File/ Import New and then browse the relevant sensor template file (csv file) and click Open to import the template file. Each sensor type has own template file. Refer to sensor's manual to download the correct file. The sensor is only active for configuration in 60 seconds since plugging the configuration cable or the power supply into the sensor.
  • Page 8: Troubleshooting

    Step 6: Write the new setting to parameter with function 16 Double click on column Setting Value of the parameter and input new setting of the parameter Uncheck the tick on Func column of the parameter, click on the arrow, select 16 and then check on the Func column to write new setting to the parameter.
  • Page 9 Distributor in Australia and New Manufacturer Zealand Daviteq Technologies Inc No.11 Street 2G, Nam Hung Vuong Res., An Lac Ward, Binh Tan Dist., Ho Chi Minh City, Vietnam. Tel: +84-28-6268.2523/4 (ext.122) Templogger Pty Ltd Email: info@daviteq.com | www.daviteq.com Tel: 1800 LOGGER Email: contact@templogger.net...