7.3.6 SETUP, [MORE], [DISPLAYS/OPTIONS], [DISPLAY TYPE]

The display can be configured for SINGLE, DUAL or TRIPLE displays. The key press sequence
changes the display parameters, the 2nd key press column shows the parameter that
changes on entry of a numeric value.
The tables show all available parameter combinations with an associated key press
sequence.
st
1
Key Press
ALT
ALT
Any key
SPEED
a
MACH
SPEED
SPEED
MACH
MACH
a. The Mach parameter changes on numeric entry.
st
1
Key Press
Ps
Ps
Ps
Any key
Qc
Pt
EPR
Pt
Qc
Pt
EPR
Qc
© 2017 General Electric Company – All Rights Reserved.
Table 7-3: Aeronautical Units Dual Display
nd
2
Key Press
SPEED
MACH
ROC
RATE
RATE
MACH
ALT
ALT
SPEED
Table 7-4: Pressure Units Dual Display
nd
2
Key Press
Qc
Pt
EPR
RATE Ps
RATE
RATE
RATE
Qc
Ps
Ps
Ps
Pt
Upper Display
ALT
ALT
ALT
CAS or TAS
MACH
MACH
ALT
ALT
MACH
Upper Display
Ps
Ps
Ps
Ps
Qc
Pt
EPR
Pt
Ps
Ps
Ps
Pt
ADTS 405 R/F Mk2 Instruction Manual-English | 85
SETUP
Lower Display
CAS or TAS
MACH
ROC
RATE CAS
RATE MACH
CAS/TAS
SPEED
MACH
SPEED
Lower Display
Qc
Pt
EPR
RATE Ps
RATE Qc
RATE Pt
RATE EPR
Qc
Qc
Pt
EPR
Qc

Advertisement