ETC Installation Guide
Integration Interface
Installation
Install to DIN rail
2
Remove the Interface from DIN rail
If for any reason you need to remove the Integration Interface from the
DIN rail, follow these instructions.
1.
2.

Connect Wiring

EchoConnect
EchoConnect terminations require Belden 8471 (or
equivalent 24-12 AWG wire), plus one 14 AWG (2.5 mm
ESD ground wire between the segment of EchoConnect
station bus and the Integration Interface.
1.
2.
3.
4.
5.
6.
Integration Interface
3
Disconnect all wiring and cap off as necessary.
Insert a flat blade screwdriver into the clip on top of the bridge,
slide it straight up, then pivot the top of the bridge off of the DIN
rail.
Ensure the Echo station power supply on the connected segment is
powered off.
Strip 5/16" (8 mm) of insulation from the end of the Belden 8471
(or equivalent) wires and one ESD ground wire.
Loosen the three screw terminals on the EchoConnect segment.
Insert the black wire (typical) into the negative (-) terminal and
tighten the screw firmly onto the wire.
Insert the white wire (typical) into the positive (+) terminal and
tighten the screw firmly onto the wire.
Insert the ESD ground wire into the last terminal (identified with a
ground symbol) and tighten the screw firmly onto the wire.
1.
Ensure the section of DIN rail to be
used is mounted securely
according to the manufacturer's
requirements. (DIN rail is provided
by others.)
2.
Hook the bottom of the
Integration Interface under the
lower DIN rail edge as shown.
3.
Pivot the bridge up and depress
until the top clip on the unit seats
completely onto the DIN rail.