TURBINE AIR - NOTE

If the turbine air is heated, check the maximum
rated temperature for the air supply tubing to be
used. Polyethylene tubing is rated for a maximum
of 80
F (27
C). Nylon tubing is rated for 200
0
0
(95
C) maximum.
0
W A R N I N G
!
† Non ignitable cleaning fluids are pre-
ferred.
† Ignitable cleaning liquids shall only
be used if, after disconnection of the high
voltage supply, all parts under high volt-
age are discharged to an energy of less
than 0.24mJ before these parts may be
serviced.
† Appropriate measures shall ensure
that the resistance to earth of the sus-
pending point of the work piece shall not
exceed 1MW measured at 500v or 1000v.
† Use only electrically conductive con-
tainer for cleaning liquids; the containers
must be earthed to ground.
TURBINE EXHAUST
Turbine air must be able to exhaust freely. If tur-
bine exhaust is required to be moved away from
the applicator, use the 12mm fitting provided. Do
not downsize tubing.
LN-9282-14
F
0
Aerobell 268 - Operation
36