AB268 A13657 ATEX PRODUCT
MARKING DEFINITIONS
Ex Certificate Number: Sira 13ATEX5176X
Sira = Notified Body performing EC-type examination
13 = Year of certification
ATEX = Reference to ATEX Directive
5 = Protection Concept Code (code 5 is titled
Encapsulation)
176 = Document serial number
X = Special conditions for safe use apply
Product Marking
0518
Ex = Specific marking of explosive protection
II = Equipment Group hazardous area
characteristics
2 = Equipment Category
G = Type of explosive atmosphere (gases,
vapors, or mists)
T6 = Temperature classification.
Power Supply Marking
0518
Special conditions for safe use:
• The AB268, Applicator shall only be used with asso-
ciated 80120-51X or 80100-51X 9060 Power Supply
according to configuration drawing A13708.
• The safe Distance of use for the Type AB268 Elec-
trostatic Bell is 204mm minimum; from the electrode to
earthed parts. The end user must ensure this distance,
as a minimum is maintained and that grounded objects
are prevented from contacting the applicator bell cup
when the applicator is energized or operating.
• The 9060 and external cascade is intended for "Safe
Area Use" only.
• The AB268 Electrostatic Bell is a potential hazard -
refer to the manufacturers instructions.
• The end user must insure that installation is in ac-
cordance with all applicable requirements of EN 50
176. This includes the means of fire protection and fire
detection being installed with this system.
• Before servicing bell insure that all voltage is com-
pletely de-energized and the bell cup is not rotating.
Minimum 1 minute wait after turbine air has been shut off.
• If ignitable fluids are used for cleaning purposes, all
parts must be completely discharged of high voltage.
• The fluid supply system must be properly grounded.
LN-9282-14
II 2 G T6
II (2) G
• If an object is within the 204mm safe distance, it must
be cleared prior to restarting and/or re-energizing the
system.
• The materials used in the construction of this equip-
ment contain levels of Al, Mg, Ti and Zi that are greater
than that allowed for EPL Ga and Gb by clause 8.3 of
EN 60079-0, therefore in rare cases, ignition sources
due to impact and friction sparks could occur. The
equipment shall therefore be protected from such
impact and friction when installed.
• The type AB268 Electrostatic Bell and type 9060
(80120-51X or 80100-51X) power supply complies with
EN 50 176: 2009. Clauses 4, 5.1, 5.2.1, 5.2.2, 5.2.3,
5.2.4, 5.3, 5.5.1, 5.5.3, 5.5.5, 5.6, 6.1, 6.4, 7.2, 7.3 and
7.4. All remaining clauses of EN 50 176: 2009 are to
be addressed during installation.
• The installer shall fix the warning sign that is supplied
with these products in a position close to the equipment;
in addition, it shall also be clearly visible to the operator.
80108
A13383
E N 5 0 1 7 6 C O M P L I A N T
A13384
A13349
Configurations
These applicators are approved when configured to
drawings shown on pages 8 thru 12.