Slide the lever.
Procedure of the SERVICE PLUG removal
KK-XZU215C
Precaution on body mounting work.
Before starting to mount a body please make sure to contact a
distributor and receive suitable advice.
Carry out mounting a body paying attention to following
precautions.
• Make sure to always wear the electric insulation equipment
(insulation rubber gloves .etc) while working.
• Prior to performing the body mounting, turn the starter switch
to OFF, pull out the SERVICE PLUG of PCU and wait more
than 7 minutes. (see following figures)
Strictly observe abouve precautions to avoid receiving electric
shock.
• Do not attach the SERVICE PLUG which removed till the end
of work.
It takes 7 minutes to discharge the electricity of high-voltage
*
condenser of the inverter.
SERVICE PLUG LID
SERVICE PLUG
Rais the lever and draw out the
SERVICE PLUG.
PCU
Slide the lever
certainly till it is locked.
Insert the SERVICE PLUG
and push down the lever.
Procedure of the SERVICE PLUG installation