Panasonic Elite Big PAC-i S-200PE3E5B Technical Data & Service Manual page 286

Dc inverter
Hide thumbs Also See for Elite Big PAC-i S-200PE3E5B:
Table of Contents

Advertisement

Checking Addresses
RC
1. Press
with one end of an unfolded paper clip
ADR
(or a similar object that can fit).
• Its current address appears on the display for 5 seconds.
• If this address corresponds to the address of a receiver, the buzzer
sounds. (If it is on ALL, the buzzer will always sound.)
• If it is on ALL, it can be operated regardless of receiver addresses.
Point the remote controller at the receiver you wish to operate and
transmit.
Matching Up Addresses
If not wall mounted type indoor unit
< Setting Remote Controller Addresses >
RC
1. Press
with one end of an unfolded paper clip
ADR
(or a similar object that can fit) for 4 seconds or longer.
• The current address number starts blinking.
RC
2. Press
to select the address of the receiver you want to
ADR
control, and press
• Every time you press
1 → 2 → 3 → 4 → 5 → 6".
• If it corresponds to the receiver's address setting, the buzzer sounds.
Note
• Set the address of the receiver as instructed in the operating instructions of your
receiver. Do not set by yourself. Contact the dealer where the product was
purchased.
For wall mounted type indoor unit
< Setting the address of the indoor unit >
1. Press [Emergency Operation]
• OPERATION lamp, TIMER lamp, and then STANDBY lamp repeatedly light one after the other for 1 second
each to indicate the unit is ready for address setting.
< Setting Remote Controller Addresses >
2. Set the address for the remote controller following the procedure under the section
" ■ If not wall mounted type indoor unit" (see this section noted above).
• Repeat Step 2 under " ■ If not wall mounted type indoor unit" if you are setting more units.
• The address setting ready status of the indoor unit ends if data transmission is not received from the remote
8
controller for 3 minutes.
• Press [Emergency Operation]
.
RC
, it cycles from "ALL (All the addresses) →
ADR
of the indoor unit for 4 seconds or longer.
on the receiver to end the address setting ready status of the indoor unit.
1
8-10
Address
Address
2
1, 2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents