Advertisement

Quick Links

READ AND SAVE THESE INSTRUCTIONS
P/N 35010041-C

user manual

Advertisement

Table of Contents
loading

Summary of Contents for Martin RUSH Club Smoke Dual

  • Page 1: User Manual

    READ AND SAVE THESE INSTRUCTIONS P/N 35010041-C user manual...
  • Page 2: Dimensions/Legal

    Dimensions/Legal All dimensions are in millimeters Dimensions/Legal...
  • Page 3 JEM™ are registered trademarks of ® ©2016 HARMAN Professional Denmark ApS. All rights reserved. Martin HARMAN Professional Denmark ApS registered in the United States and/or other countries. Features, specifications, and appearance are subject to change without notice.
  • Page 4: Table Of Contents

    Contents Dimensions/Legal ........................2 Contents ............................ 4 Safety information ........................5 Product overview ........................8 Product description ........................ 8 Features at a glance ......................8 Product details ........................9 Quick Start ..........................12 Setting up ..........................12 Making fog and haze ......................12 Installation and setting up ......................
  • Page 5: Safety Information

    If the machines or any cables connected to it are in any way damaged, defective, wet, or show signs of overheating, stop using the machines and contact Martin Service and Support for assistance. If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agent.
  • Page 6 Do not spill fluid over or inside the machines. If fluid is spilled, disconnect AC power and clean with a damp cloth. If fluid is spilled onto electronic parts, take the machines out of service and contact Martin Service and Support for advice.
  • Page 7  Do not point effect output directly at a person’s face or at face height. For the latest user documentation and other information for this and all Martin products, please visit the Martin website at http://www.martin.com If you have any questions about how to install, operate or service the machines safely, please contact your Martin distributor, dealer, or contact Martin Service and Support.
  • Page 8: Product Overview

    P r o d u c t d e s c r i p t i o n The RUSH Club Smoke Dual is a top of the range atmospheric system from Martin Professional featuring multiple remote fog or haze heads with a base pump/fluid unit.
  • Page 9: Product Details

    P r o d u c t d e t a i l s Fog Head If suspending overhead: Loop safety cable under hanging bracket and secure Control input from pump unit Control output to next head Mains power switch Mains inlet cable Status...
  • Page 10 If suspending overhead: Loop safety cable under Haze Head hanging bracket and secure Control input from pump unit Control output to next head Mains power switch Mains inlet cable Status Haze fan inlet Fluid inlet Indicators connection Heat (red) Ready (green) Haze outlet WARNING! High temperature...
  • Page 11 Base pump unit External fluid connection (Top and bottom) Fluid Control AVR socket outputs to connections to heads heads Mains power inlet 3-pin DMX Mains power in/out switch Digital remote control socket Hinged door to fluid reservoir 5-pin DMX in/out Digital control panel Product overview...
  • Page 12: Quick Start

    Connect the heads to the base unit with RJ45 control cables. If you are connecting 2 heads to an output, the second head is linked from the first. Fill the fluid reservoir in the base unit with RUSH Club Smoke Dual Fluid only. Use of other fluid will void the warranty.
  • Page 13: Installation And Setting Up

    “Safety information” on page 5. L o c a t i o n The RUSH Club Smoke Dual heads are designed to be located on the floor or may be suspended using the hanging bracket. The heads can operate in any orientation from vertically down to vertically up.
  • Page 14: Setting Up

    S e t t i n g u p Fill the fluid tank only with Martin RUSH Club Smoke Dual Fluid (see page 23). Up to two heads of the same type (fog or haze) may be connected to each fluid output of the pump unit.
  • Page 15 Connection of two heads on one channel T-connector Connection of fully loaded system Haze heads on channel 1 T-connector Installation and setting up...
  • Page 16: Final Checks

    5.  the fluid is one of the genuine Martin fluids listed under fluid options on page 23.  the system is electrically grounded (earthed) ...
  • Page 17: Control Settings

    Control settings O v e r v i e w The Digital Control Panel on the side of the base unit allows you to configure the system using option menus. Enter/store button Digital display  Menu previous/next Value down/up buttons buttons Quick access buttons PRIME1 PRIME2 PRIME3 PRIME...
  • Page 18: Setting Output Density For Haze Heads

    S e t t i n g o u t p u t d e n s i t y f o r H a z e h e a d s Use the Menu Previous / Next buttons to select the  option. Use the Up/Down buttons to select the density from ...
  • Page 19: Priming System With Quick Access Buttons

    Use the Up/Down buttons to change the option to . Press the Enter button to start the priming function. The pump unit will pump at full power for a short time to purge air from the pipes inside the unit. To exit this menu if you decide not to activate the Prime function, select ...
  • Page 20: Remote Control

    (not the 3-pin DMX plug). The remote control is powered through its cable by the RUSH Club Smoke Dual; no batteries are required. The cable may be extended to up to 25 m (82 ft.) with a 3-pin XLR DMX cable.
  • Page 21: Dmx Control

    To set the address, see “18” on page 18. The RUSH Club Smoke Dual requires 4 DMX channels. For example if the RUSH Club Smoke Dual is set to DMX address 100, channel 1 will be controlled by address 100, channel 2 will be controlled by address 101, channel 3 by address 102 and channel 4 by address 103.
  • Page 22 Channel 1 DMX value Function Macro description Default range value Fog/haze 0-12 Idle range None output 1 13- 240 Output 0- level 100% 241 -255 Output 100% Channel 2 DMX value Function Macro description Default range value Fog/haze 0-12 Idle range None output 2 13- 240...
  • Page 23: Effect Fluid Types

    Effect fluid types The RUSH Club Smoke Dual must only be used with RUSH Club Smoke Dual Fluid. Martin supplies high quality fog fluids that are based on ultra-pure deionized water. No other fluid is suitable for use. RUSH Club Smoke Dual Fluid...
  • Page 24: Basic Service

    C l e a n i n g a n d P r e v e n t a t i v e M a i n t e n a n c e P r o c e d u r e : Use Martin Pro Clean and Storage Fluid after every 200 hours of operation or monthly depending on usage and duty cycle.
  • Page 25: Fuse Replacement

    Remove the spent fuse and replace with one of exactly the same size and rating. The fuse type is indicated below. Contact Martin Service if the fuse blows repeatedly. Fog head 120 V = 10 AT 230 V = 6.3 AT...
  • Page 26: Troubleshooting

    Troubleshooting Problem Probable cause(s) Suggested remedy Wait until  message System not at operating temperature no longer shown System will not produce fog/haze when control panel  or  set to 0 Increase setting set to RUN or remote  set to 0 Increase setting control Fog/Haze switch turned on...
  • Page 27: Status Messages

    (bottom right hand button on control display) The system has detected an error with its calibration  settings and will not operate. Call Martin Service. The system has detected an error in the temperature  sensor and will not operate. Call Martin Service.
  • Page 28: Specifications

    Technical Specifications P h ys i c a l Fog head Length .................... 356 mm (14 in.) Width ................... 259 mm (10.1 in.) Height ..................... 169mm (6.7 in.) Height with hanging bracket ............278 mm (11 in.) Weight .................... 7.6 kg (16.8 lb.) Haze head Length ..................
  • Page 29 Pump Unit Housing ................... Steel and aluminum Color ....................... Black Fluid pump ............3 oscillating piston, high pressure Fluid system ..........10 l concealed and removable reservoir Optional external fluid connection kit (top and bottom inlet) Fluid Management ............... Fluid out sensing I n s t a l l a t i o n Fog and Haze Heads Mounting ..................
  • Page 30 Pump Unit AC Power ..............220-240 V, 50/60 Hz, 180 W Main fuse ..............3.15 AT (slow-blow), 250 V Typical power and current ..............180 W, 0.9 A* US Models Fog Head AC power ..............100-130 V, 50/60 Hz, 1000 W Main fuse .................
  • Page 31 Electronic Equipment), as amended by Directive 2003/108/EC, where applicable. Help preserve the environment! Ensure that this product is recycled at the end of its life. Your supplier can give details of local arrangements for the disposal of Martin products. Technical Specifications...
  • Page 32 • Olof Palmes Allé 18 • 8200 Aarhus N • Denmark Tel: +45 8740 0000 • Fax: +45 8740 0010...

Table of Contents