Omron Sysmac NY Series Hardware User Manual page 166

Ipc machine controller industrial box pc
Hide thumbs Also See for Sysmac NY Series:
Table of Contents

Advertisement

5 Installation
I/O Connector Wiring Procedure
Use the following procedure to wire the I/O connector.
1
Ensure the I/O connector is not connected to the Box PC.
2
Remove the sheath from the wires.
Precautions for Safe Use
Observe the following precautions to prevent broken wires.
• When you remove the sheath, be careful not to damage the conductor.
• Connect the conductor without twisting the wires.
• Do not weld the conductors. Doing so may cause the wires to break with vibration.
3
Remove the I/O connector from the Box PC.
4
Insert a screwdriver in the small groove above the cable entry
then push the wire all the way to the back of the cable opening
1
2
5
Remove the screwdriver.
Do not apply stress to the cable after you have connected the wires.
5-40
7 mm
NY-series Industrial Box PC Machine Controller Hardware User's Manual (W556)
1
to unlock the cable entry and
2
.

Advertisement