iRay Technology Mars1417X User Manual

iRay Technology Mars1417X User Manual

Wireless digital flat panel

Advertisement

Wireless Digital Flat Panel
Mars1417X
User Manual
Version :A1
Doc ID :042-201-02
Release Date::2020.10.13
Before operating, please read this user manual and pay attention to all safety precautions.
Please ensure that this user manual is properly maintained so that it can be accessed at any time
(reserve).
E
Please use it correctly based on full understanding of the content.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mars1417X and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for iRay Technology Mars1417X

  • Page 1 Wireless Digital Flat Panel Mars1417X User Manual Version :A1 Doc ID :042-201-02 Release Date::2020.10.13 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user manual is properly maintained so that it can be accessed at any time (reserve).
  • Page 3 To Customers Congratulations on your purchase of the Wireless Digital Wireless Digital Flat Panel Detector (hereinafter referred to as Mars1417X) which is manufactured by iRay Technology Company Ltd. (Hereinafter referred to as iRay). Please take time to read through this user guide in order to utilize the product effectively. We hope you enjoy the experience with iRay Mars1417X.
  • Page 4 Wireless Digital Flat Panel Detector Mars1417X Caring for your environment This symbol indicates that this product is not to be disposed of with your residential commercial waste. Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste. Improper handling of this type of waste could have a negative impact on health and on the environment.
  • Page 5 All rights reserved No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1417X. Trademarks The iRay name and iRay logo are registered trademarks of iRay Technology Co. Ltd.
  • Page 6 Wireless Digital Flat Panel Detector Mars1417X Symbols and Conventions User Manual of Mars1417X...
  • Page 7 Identify conditions under which improper use of the product may cause property damage. Indicate a prohibited operation. Indicate an action that must be performed Indicate important operations and restrictions. Indicate operations for reference and complementary information. User Manual of Mars1417X...
  • Page 8 Labels and markings on the equipment Symbol Description The contents of the label and mark on iRay Mars1417X product are indicated as below: Caution: please refer to the instructions in the user manual. Indicates that the equipment has passed CE testing and the CE Notified Body number follows it.
  • Page 9 Handled with care. Operational temperature limits. Storage temperature limits. Fragile Keep away from sunlight Keep dry Humidity limits. Keep the equipment up right. Do not roll the transportation package. Stacking limit number. IP56 IP56 for the detector User Manual of Mars1417X...
  • Page 10 Wireless Digital Flat Panel Detector Mars1417X Detector symbol : device is for prescription use only User Manual of Mars1417X...
  • Page 11: Table Of Contents

    Product Lifetime ..................80 8.3. Regular Inspection and Maintenance ............80 8.4. Repair ...................... 80 8.5. Replacement Parts Support ..............80 APPENDIX A INFORMATION OF MANUFACTURES ............83 APPENDIX B INFORMATION OF EUROPE REPRESENTATIVE ........84 User Manual of Mars1417X...
  • Page 12: Safety Information

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 1. Safety Information 1.1. Safety Precautions .................. 11 1.2. Notes for Using ..................20 User Manual of Mars1417X...
  • Page 13: Safety Precautions

    Do not connect the equipment with anything other than specified. Doing so may result in fire or electric shock. All the patients with active implantable medical devices should be kept away from the equipment. User Manual of Mars1417X...
  • Page 14 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Power supply Do not operate the equipment using any type of power supply other than the one indicated on the rating label. Otherwise, it may result in fire or electric shock. Do not handle the equipment with wet hands.
  • Page 15 Otherwise, you may get an electric shock that could result in death or serious injury. Be sure to hold the plug or connector to disconnect the cord. If you pull the cord, the core wire may be damaged, resulting in fire or electric shock. WARNING User Manual of Mars1417X...
  • Page 16 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Handling Never disassemble or modify the equipment. No modification of this equipment is allowed. Parts of the Mars1417X that are not serviced or maintained while in use with the patient. Doing so may result in fire or electric shock. Also, since the...
  • Page 17 For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual. Otherwise, electric shocks may occur. User Manual of Mars1417X...
  • Page 18 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X CAUTION Installation and Do not install the equipment in any of the locations environment of listed below. Doing so may result in failure, malfunction, equipment falling, fire or injury. Close to facilities where water is used...
  • Page 19 In such a situation, protect the equipment with a disposable cover as necessary. Turn OFF the power and pull out the plug to each piece of equipment for safety when not used. CAUTION Handling Handle the equipment carefully. Do not submerge the equipment in water. User Manual of Mars1417X...
  • Page 20 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X The internal image sensor may be damaged if something hits against it or it is dropped. Do not place excessive weight on the equipment. Be sure to use the equipment on a protected foam.
  • Page 21 1. Safety Information CAUTION Do not close to fire, do not use in high temperature Do not invert positive and negative pole Do not contact with metal in case of short circuit User Manual of Mars1417X...
  • Page 22: Notes For Using

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 1.2. Notes for Using When using the product, take the following precautions. Otherwise, problems may occur and the product may not function correctly. Before exposure Be sure to check the connection of all the parts are set properly & check the detector is kept ...
  • Page 23 Wipe it with a cloth slightly damped with a neutral detergent. Do not use solvents such as  alcohol, benzene and acid. Doing so may damage the surface of the product. It’s recommended to use a waterproof non-woven cover as the isolated layer between  product and the blooding patient. User Manual of Mars1417X...
  • Page 24: General Description

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 2. General Description 2.1. Product Description ................... 23 2.2. Principle ..................... 23 2.3. Scope ......................23 2.4. Characteristics ................... 24 Intended Use ....................24 2.6. Environment ....................29 2.7. Product Components ................. 29 2.8.
  • Page 25: Product Description

    1. Safety Information 2.1. Product Description Mars1417X is a cassette-size wireless X-ray Wireless Digital Wireless Digital Flat Panel Detector based on amorphous silicon thin-film transistor technology. It is designed to provide the high quality radiography image which contains an active matrix of 3500×4300 with 100um pixel pitch, the TFT module has a pixel matrix of 3584*4352.
  • Page 26: Characteristics

     Intended Use Mars1417X is indicated for digital imaging solutions designed to provide general radiographic diagnosis for human anatomy including both adult and pediatric patients. It is intended to replace film/screen systems in all general–purpose diagnostic procedures. The device is not intended for mammography or dental applications.
  • Page 27 To help reduce the risk of excessive radiation exposure, you should follow the ALARA (As Low As Reasonably Achievable) principle and seek to reduce radiation dose to only the amount necessary to obtain images that are adequate clinically. Additional guidance and recommendation are provided by the Alliance for Radiation User Manual of Mars1417X...
  • Page 28 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Safety in Pediatric Imaging (Image Gently Alliance) https://www.imagegently.org/ Table 1 : Techniques for Typical Body Parts Body Parts Patient Size Grid Very Low Birth Weight (Less than 1.5Kg) Abdomen Low Birth Weight (Between 1.5 AP/PA and 2.5Kg)
  • Page 29 Newborn Infant Child Extremities Preadolescent AP/PA Adolescent Adult Small Regarding adult details techniques of Extremities, please refer to the table “Techniques for Adult Extrimities” Table 2: Techniques for Adult Extrimities Adult Extemities List Grid Ankle - AP iRay Technology Co.
  • Page 30 Wrist - PA Wrist – Lateral ESSENTIAL PERFORMANCE According to the Mars1417X INTENDED USE and the result of risk management, image acquisition and data transmission are defined as ESSENTIAL PERFORMANCE. Getting dark image proves that ESSENTIAL PERFORMANCE does not influence INTENDED USE.
  • Page 31: Environment

    2.General Description 2.6. Environment Temperature Humidity Atmospheric Pressure Operating 10~35℃ 5~90% RH 700~1060mbar Storage -20~55℃ 5~95% RH 600~1060mbar 2.7. Product Components Item Picture Description Mars1417X Detector 1pcs Medical Adapter 1pcs AC Power Cable 1pcs User Manual of Mars1417X...
  • Page 32 Wireless Digital Flat Panel Detector Mars1417X Gigabit Ethernet Cable 1pcs 2.7.1. Detector iRay Technology Co.
  • Page 33: Specification

    2. General Description 2.7.2. Indicator 2.8. Specification 2.8.1. Basic Item Specification Model Mars1417X Image Sensor a-Si (Amorphous Silicon) TFT Scintillator Pixel Size 100um Fill Factor Effective Array 3500x4300 iRay Technology Co.
  • Page 34 Wireless Digital Flat Panel Detector Mars1417X Effective Area (H x V) 35mm×43mm Spatial Resolution 4.3 lp/mm Image Transfer WIFI Full Image Time <5s (with 1s XWin, from end of XWin) Cycle Time 35W @ Full-Running Power Consumption 7.5W @ Idle Dimension (L ×...
  • Page 35: Basic Operation

    2. General Description 3. Basic Operation 3.1. Preparation ....................34 3.2. Routine Operation ..................35 3.3. Battery Charger Installation ................ 37 iRay Technology Co.
  • Page 36: Preparation

    3.1.2. Adapter Detector supports an external adapter powered, It gets CB certificate No. SG PSB-MD-00005 and NRTL certificate No. U8V 093768 0016.The ports defined as bellow: Definition Voltage Range Rated Current DC Power Negative 0~0.5V 0~0.42A User Manual of Mars1417X...
  • Page 37: Routine Operation

    15%, or DC power is connected. After booting up, users can check the indicator of the detector. Power indicator: Status Power Indicator Lighting Status Battery Capacity DC Input Description Detector is off User Manual of Mars1417X...
  • Page 38 Wireless Digital Flat Panel Detector Mars1417X Green ON Detector is on ≥7% & <15% Orange Blinking Detector is on ≥15% & <95% Green Blinking Detector is on Green&Orange <95% Detector is off Blinking Link indicator: Link Indicator Lighting Status Description...
  • Page 39: Battery Charger Installation

    3.Basic Operation 3.3. Battery Charger Installation Operation Figure Unload Battery from battery  charger. Insert battery into battery  charger. Note the interface position  as figure. Press the battery to the  bottom of battery compartment. User Manual of Mars1417X...
  • Page 40: Software Setup

    System requirement ................39 4.2. Environment setup................... 39 4.3. Wired Connection (for setting&maintenance) ......... 39 4.4. Software UI ....................42 4.5. List of the HAZARDOUS SITUATIONS resulting from a failure of the IT- NETWORK ......................60 User Manual of Mars1417X...
  • Page 41: System Requirement

    Connect the power cable and data cable to the detector as figure 3-3-1, please mind that there are two type-c interfaces on the detector, the one closes to the edge of the battery component is for data and command, the other one is for service. User Manual of Mars1417X...
  • Page 42 Wireless Digital Flat Panel Detector Mars1417X Figure 3-3-2 The default IP address (IPv4) of the detector is 192.168.8.8, the PC address (IPv4) should be configured as 192.168.8.xxx, which should be the same as the value of parameter “Cfg_HostIP”in file “*\work_dir\Mars1417X\config.ini”...
  • Page 43 4. Software Setup Figure 3-3-3 On the main window of Home page, select the instance of“Mars1417X” and use the “Connect” button the build the connection. Figure 3-3-4 After finishing building the connection, click “Read Config”button on the “Wifi”tab of “Detector”...
  • Page 44: Software Ui

    Wireless Digital Flat Panel Detector Mars1417X For Client mode, user can add the information of the access point with button “Add”, and set the default access point that the detector should connects to with button “Select”. Figure 3-3-6 After click “Write Config”button, the new setting of the wifi will be valid after the status shows succeed.
  • Page 45 Display the name of detector Display the SN of detector Product Type Display the type of detector State Display the connection state (Bind,Unknown, Ready etc.) Button Function description Connect Click this button to connect the selected detector. User Manual of Mars1417X...
  • Page 46 Wireless Digital Flat Panel Detector Mars1417X Close Click this button to disconnect the selected detector. Add work directory Remove Remove work directory Syncbox Open Syncbox configuration window(Optional device) 4.4.2. Acquire Page This page is used to acquire image under different work mode, and user can select correction options too.
  • Page 47 Value of the current cursor at the point Width Image width Height Image height Frame rate Frames Display the frame count Rotate the image clockwise, 90 degrees every time. Rotate the image anticlockwise, 90 degrees every time. Mirror Open or close mirror User Manual of Mars1417X...
  • Page 48 Wireless Digital Flat Panel Detector Mars1417X ROI tool,to view the image of the AVG, SV, SNR and other parameters with right click. Press "ctrl" key, can create several ROI area. WW/WL Auto adjust WW/WL based on selected area by right button of mouse.
  • Page 49 Parameter write region: write parameter. Entered value of the corresponding parameter in this area can be write to detector. Operation region: functional operation buttons area. Status bar region: status bar for detector state and information of reading or writing parameters, etc. User Manual of Mars1417X...
  • Page 50 Wireless Digital Flat Panel Detector Mars1417X Configuration parameters description as below: Name Description Configurable Product No. Type of detector product Serial No. Serial number of the detector Main Version Firmware version number of the FPGA Read Version MCU Version Firmware version number of the MCU...
  • Page 51 Upload detector log to the specified directory Sensor  The mainly function in this page is to probe the temperature and humidity of the detector. Click “Read” button to get the value of the temperature or humidity. User Manual of Mars1417X...
  • Page 52 Wireless Digital Flat Panel Detector Mars1417X Sensor type Explanation Temperature Read detector temperature Humidity Read detector humidity Battery Read the capacity of the battery Wifi  User can config the wireless connect parameters on this tab. Images  You can Query and upload Images from detector to Workstation.
  • Page 53 4. Software Setup 4.4.5. Calibrate Page Offset, Gain, Defect calibrate files can be generated and managed in this page. Click “Start Generate Templates” to enter generating templates page. User Manual of Mars1417X...
  • Page 54 Wireless Digital Flat Panel Detector Mars1417X SubTab Description Mode&Files Manage template files Create Offset Create Offset template Create Gain Create Gain template Create Defect Create Defect template Mode&Files page Description Import to Workdir Copy template file into current calibration directory.
  • Page 55 Click PREP button, then exposure after Acquire button enable. After receving the PREP request, the detector needs some time to be ready, the decounting bar will apear when the exposure window is opened. After exposure user can click Acquire button to acquire the X- Ray image. User Manual of Mars1417X...
  • Page 56 Wireless Digital Flat Panel Detector Mars1417X The gain template generation process needs 5 images total, the UI gives the recommended KV and target value, user can use different ones if needed. After accepting the current image, the “Stage” will turn to 2/5, 3/5 and so on.
  • Page 57 If “Download to FPD after generation” is checked, then the download UI will appear after finishing generating. User can refer to the part of “Generate Defect Template File" When the generating process is finished, the UI will give the message of successful. User Manual of Mars1417X...
  • Page 58 Wireless Digital Flat Panel Detector Mars1417X Generate Defect Template File  The process of generate defect map is quite similar with the one of gain map. On the “Create Defect” page, user can start the generating process by “Start” button.
  • Page 59 The correction map also can be managed at anytime on the page of “Mode&Files”. Choose the item of “Default” in the Subset settings part and click “Download to FPD” to finish downloading the maps into the detector. Upload the correction files  User Manual of Mars1417X...
  • Page 60 Wireless Digital Flat Panel Detector Mars1417X The correction maps can be uploaded to the workstation too. Choose the gain or defect in the “Fpd template files”and the “Default” directory in the “Subset settings”, then click the “Upload to workdir”. When the upload process is finished, the UI will give the message.
  • Page 61 This page provides ROI tool, which can see the AVG, SNR, and other properties of the choosen image area by right mouse button. This page provides WW/WL tool as Acquire page . Click this button to auto adjust WW/WL based on selected area by right button of mouse. User Manual of Mars1417X...
  • Page 62: List Of The Hazardous Situations Resulting From A Failure Of The It

    Wireless Digital Flat Panel Detector Mars1417X Image Properties& Description Image Process window width window level PosX X coordinates of the current cursor at the point PosY Y coordinates of the current cursor at the point Value Value of the current cursor at the point...
  • Page 63: Operation Instructions For Image Acquisition

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 5. Operation Instructions for Image Acquisition 5.1. Steps for acquiring image ................ 62 5.2. Software Mode ..................62 5.3. AED Mode ....................64 5.4. After use ....................65 5.5. Firmware Upgrade ................... 65...
  • Page 64: Steps For Acquiring Image

    Acquire images in the selected mode  To Acquire X-ray image is the main operation of Mars1417X. Most importantly, detector should build synchronization with X-ray generator. Mars1417X has one synchronization modes to acquire X-ray image, which is Software Mode.
  • Page 65 Work Flow(Prep+Acq) RAW X-Ray image RAW offset(Or corrected) Cmd_Prep Ack_Prohibit Ack_Enable X-Ray RAW Preview Cmd_SingleAcq (If HW-offset is disabled) image XWIN2 X-Ray XWIN2 Offset IDLE Prepare (dynamic) imaging (dynamic) imaging Send Cmd“Prep” on UI “Acquire” page. User Manual of Mars1417X...
  • Page 66: Aed Mode

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X After receiving the Cmd_Prep, it will start the prepare process, and send back the acknowlage of “Prohibit” and “Enable”, the “XWIN” will be started. The max XWIN is configured by parameter “Exp Window Time” on “Detector” page “Parameter”...
  • Page 67: After Use

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 5.3.3. RAW X-Ray image RAW Offset(Or corrected) RAW Preview X-Ray Info (If HW-offset is disabled) image XWIN1 X-Ray XWIN1 Offset IDLE (fixed) imaging (fixed) imaging For Freesync mode, there is no low power state.
  • Page 68 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X The firmware upgrade package may contain firmware of several units: ARM, FPGA, MCU. Mars1417X_IMAGE_44_ALL_20XX_XX_XX.ifrm Word “ALL” indicates the file contains the firmware upgrade file for all units. Mars1417X_IMAGE_44_ARM_20XX_XX_XX.ifrm Word “ARM” indicates the file is only for ARM.
  • Page 69 5. Operation Instructions for Image Acquisition User Manual of Mars1417X...
  • Page 70: Regulatory Information

    6. Regulatory Information 6.1. Medical Equipment Safety Standards ............. 69 6.2. Guidance and Manufacture’s Declaration for EMC ......... 69 6.3. Radio Frequency Compliance Information ..........72 6.4. Battery Safety Standards ................ 75 6.5. Product Label ..................75 User Manual of Mars1417X...
  • Page 71: Medical Equipment Safety Standards

    Medical electrical equipment – Part 1: General CAN/CSA-C22.2No.60601-1:14 requirements for basic safety and essential performance 6.2. Guidance and Manufacture’s Declaration for EMC 6.2.1. EMI Compliance Table Emissions  Phenomenon Compliance Electromagnetic environment RF emissions CISPR 11 Professional healthcare facility environment User Manual of Mars1417X...
  • Page 72 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Group 1, Class B Harmonic IEC 61000-3-2 Professional healthcare facility environment distortion Class A Voltage IEC 61000-3-3 Professional healthcare facility environment fluctuations and Compliance flicker 6.2.2. EMS Compliance Table Enclosure Port ...
  • Page 73 Electromagnetic Compatibility (EMC)  Mars1417X requires special precautions regarding EMC and needs to be installed only by iRay or authorized personnel and put into service according to EMC information provided in the user manual. Mars1417X in use may be susceptible to electromagnetic interference from portable and mobile RF communications such as mobile (cellular) telephones.
  • Page 74: Radio Frequency Compliance Information

    The use of accessories, transmitters and cables other than those specified by this User Manual, with the exception of accessories and cables sold by iRay of Mars1417X as replacement parts for inner components, may result in increased emission or decreased immunity.
  • Page 75 This device is designed and manufactured not to exceed the emission limits for exposure to radio frequency (RF) energy set by the Federal Communications Commission of the United States. During SAR testing, this device was set to transmit at its highest certified power level in all User Manual of Mars1417X...
  • Page 76 0 mm between this device and your body. RF exposure compliance with any body-worn accessory, which contains metal, was not tested and certified, and using such body-worn accessory should be avoided. User Manual of Mars1417X...
  • Page 77: Battery Safety Standards

    - Part 2: Lithium systems UN38.3 United Nations Recommendations on the Transport of dangerous goods Manual of tests and Criteria ST/SG/AC.10/11/Rev.6/Amend.1&Amend.1 6.5. Product Label Mars1417X Detector Label User Manual of Mars1417X...
  • Page 78 Flat Panel Detector Mars1717X 6.6. Battery Charger Label User Manual of Mars1417X...
  • Page 79 6.Regulatory Information Battery Label User Manual of Mars1417X...
  • Page 80: Trouble Shooting

    7. Trouble Shooting 7. Trouble Shooting Please refer to service manual. If the problem persists, turn off the panel and contact iRay service department ( service@iraygroup.com ). We would provide the best service. User Manual of Mars1417X...
  • Page 81: Service Information

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X 8. Service Information 8.1. Service Office Information ............... 80 8.2. Product Lifetime ..................80 8.3. Regular Inspection and Maintenance ............80 8.4. Repair ...................... 80 8.5. Replacement Parts Support ..............80 User Manual of Mars1417X...
  • Page 82: Service Office Information

    If problem cannot be solved, contact your sales representative or local iRay dealer for repairs. Please refer to the label and provide the following information: Product Name: Series Number: Description of Problem: as clearly as possible. 8.5. Replacement Parts Support User Manual of Mars1417X...
  • Page 83 8. Service Information Main parts (parts required to maintain the function of the product) of this product will be stocked for 7 years after discontinuance of production for repairing. User Manual of Mars1417X...
  • Page 84 Wireless Digital Wireless Digital Flat Panel Detector Mars1417X APPENDIX A INFORMATION OF MANUFACTURES ............76 APPENDIX B INFORMATION OF EUROPE REPRESENTATIVE ........77 User Manual of Mars1417X...
  • Page 85: Appendix A Information Of Manufactures

    APPENDIX Appendix A Information of Manufactures COMPANY: iRay Technology Co., Ltd. ADDRESS: RM202, Building 7, No. 590, Ruiqing RD. , Zhangjiang East, Podong, Shanghai, China ZIP CODE: 201201 TELEPHONE: +86 021-50780560 FAX: +86 021-50780560 HOMEPAGE: WWW.IRAYGROUP.COM User Manual of Mars1417X...
  • Page 86: Appendix B Information Of Europe Representative

    Wireless Digital Wireless Digital Flat Panel Detector Mars1417X Appendix B Information of Europe Representative COMPANY: iRay Europe GmbH ADDRESS: IN DEN DORFWIESEN 14, 71720 OBERSTENFELD GERMANY ZIP CODE: TELEPHONE: +49-7062-977 88 00 FAX: +49-7062-976 0571 HOMEPAGE: WWW.IRAYEUROPE.COM User Manual of Mars1417X...

Table of Contents

Save PDF