iRay Technology Mars1417V User Manual

iRay Technology Mars1417V User Manual

Wireless digital flat panel detector
Hide thumbs Also See for Mars1417V:

Advertisement

Wireless Digital Flat Panel Detector
Mars1417V
User Manual
Document Version:A2
Document ID:059-201-02
Release Date:2018-08-20
Before operating, please read this user manual and pay attention to all safety precautions.
Please ensure that this user's manual is properly maintained so that it can be accessed at
any time ( reserve ).
Please use it correctly on the basis of full understanding of the content.
E

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Mars1417V and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for iRay Technology Mars1417V

  • Page 1 Wireless Digital Flat Panel Detector Mars1417V User Manual Document Version:A2 Document ID:059-201-02 Release Date:2018-08-20 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time ( reserve ).
  • Page 3 Please take time to read user manual to utilize the product effectively. We hope you enjoy the experience with Mars1417V (configuration:Mars1417V2 ).
  • Page 4 Mars1417V Digital Flat Panel Detector User Manual Caring for your environment This symbol indicates that this product is not to be disposed of with your residential or commercial waste Recycling iRay Equipment Please do not dispose of this product with your residential or commercial waste.
  • Page 5 This symbol indicates the name and address of manufacturers. Labels and markings on the equipment The contents of the labels and markings on Mars1417V (configuration:Mars1417V2 ) product are indicated below: Diagram Connotation Caution: please refer to the instructions in user manual.
  • Page 6 Mars1417V Digital Flat Panel Detector User Manual This symbol indicates that the product has passed CE certification and followed by CE number. This symbol is used to identify the manufacture series number which is after, below or adjacent to the symbol. The series...
  • Page 7 Package symbol, keep away from sunlight. Package symbol, keep dry. This symbol indicates the humidity limits. Keep the product up right Do not roll the transportation package. This symbol indicates stacking limit number. Type-B applied part iRay Technology Co. Ltd.
  • Page 8: Table Of Contents

    Mars1417V Digital Flat Panel Detector User Manual SAFETY ..........................9 Safety precautions ..........9 Notes for Using ............. 14 GENERAL DESCRIPTION ....................17 Scope ..............17 Model ..............17 Characteristic ............18 Intended use/ essential performance/ application specification Essential performance .......... 18 The relative position between patient and detector19 Product Components ..........
  • Page 9 Product Lifetime ..........102 Regular Inspection and Maintenance ....102 Repair ..............102 Replacement Parts Support ....... 102 APPENDIX A INFORMATION OF MANUFACTURES ............104 APPENDIX B INFORMATION OF MEDICAL DEVICE DIRECTIVE EUROPEAN REPRESENTATIVE ......................105 iRay Technology Co. Ltd.
  • Page 10 Mars1417V Digital Flat Panel Detector User Manual 1. Safety 1.1 Safety precautions ................9 1.2 Notes for Using ................14 iRay Technology Co. Ltd.
  • Page 11: Safety

    Doing so may result in fire or electric shock.  To avoid the risk of electric shock, this product must only be connected to power supply with protective earth. Not doing so may result in fire or electric shock. iRay Technology Co. Ltd...
  • Page 12 Mars1417V Digital Flat Panel Detector User Manual  Securely plug the power cord into the AC outlet. If contact failure occurs, or if metal objects come into contact with exposed metal prongs of the plug, fire or electric shock may result.
  • Page 13 Otherwise, it may cause a malfunction of the product or injury of the user due to tripping over the cable.  Non-medical equipment such as battery charger, access point and infrared register tools cannot be used in patient’s vicinity. iRay Technology Co. Ltd.
  • Page 14 Mars1417V Digital Flat Panel Detector User Manual  Always connect three-core power cord plug to a Power supply grounded AC power outlet.  To make it easy to disconnect the plug at any time, avoid putting any obstacles near the outlet. Otherwise, it may not be possible to disconnect the plug in an emergency.
  • Page 15 Otherwise, the product may fall over, resulting in injury to user or patient, or may flip over, resulting in damage to the inner device. Keep the same load on the product when acquiring image. The image will be incorrect. CAUTION iRay Technology Co. Ltd.
  • Page 16: Notes For Using

    Mars1417V Digital Flat Panel Detector User Manual  Do not close to fire, do not use in high temperature  Do not invert positive and negative pole  Do not contact with metal in case of short circuit  Do not insert sharp objects into battery ...
  • Page 17 Doing so may damage the surface of the product.  It’s recommended to use a waterproof non-woven cover as the isolated layer between product and the blooding patient. Applied part  The front and back of detector is application part. iRay Technology Co. Ltd.
  • Page 18 Mars1417V Digital Flat Panel Detector User Manual 2. General Description GENERAL DESCRIPTION ....................17 Scope ..............17 Model ..............17 Characteristic ............18 Intended use/ essential performance/ application specification Essential performance .......... 18 The relative position between patient and detector19 Product Components ..........
  • Page 19: General Description

    Panels’ scitinator has two options which are Standard GOS(Gadolinium Sulfoxylate) and CsI(Caesium Iodide). However the most great improvement is Mars1417V supports wireless communication between panel and Workstation. Mars1417V’s power supply includes battery. Mars1417V can be used as a real portable panel. 2.1 Scope This manual contains information about the Mars1417V.
  • Page 20: Characteristic

    This panel is not intended for mammography or dental applications. 2.5 Essential performance According to the Mars1417V series intended use and the result of risk management, getting imaging and function of data transmission is defined as essential performance. Getting qualified dark image proves that essential performance does not influence intended use.
  • Page 21: The Relative Position Between Patient And Detector19

    2.6 The relative position between patient and detector Because of the crosstalk effect of Amorphous silicon flat-panel detector, Pay attention to the relative position of patient and detector, the recommended position as shown below, Otherwise, the image is prone to abnormal light lines. iRay Technology Co. Ltd.
  • Page 22: Product Components

    Mars1417V Digital Flat Panel Detector User Manual 2.7 Product Components Mars1417V comes with both DC power supply and battery package. Once powered on, it would build a connection with Workstation through Ethernet cable (only for service) or Wireless connection. Item...
  • Page 23 2. General Description 1pcs Gigabit Ethernet Cable 1 pcs AC Power Cable 1 pcs DC Power Cable 3.5 m Battery Charger 1pcs 1pcs Gain correction data CD-Rom Defect correction map Manual iRay Technology Co. Ltd.
  • Page 24: Optional Product Component

    Mars1417V Digital Flat Panel Detector User Manual 2.8 Optional Product Component Item Description Wireless AP Device 1pcs Infrared Device 1pcs 2.9 Components Description 2.9.1 Detector External Signals Inpu Control Panel Item Name Description DC Jack 24V DC input Detector Indicator Detector indicator of control panel iRay Technology Co.
  • Page 25 For service engineer to maintenance Battery Lock The lock button for detaching battery Detector Label Product information. 2.9.2 Battery Item Name Description Battery Label Battery Interface 8 Pin Battery connector Pilot Pin Indicator Installation direction indicator iRay Technology Co. Ltd.
  • Page 26 Mars1417V Digital Flat Panel Detector User Manual 2.9.3 Battery Charger Item Name Description Battery Interface 8 Pin Battery connector Capacity Indicator The indicator definition is as follow Power Indicator The indicator definition is as follow Hand Pull Position The limit ball plug...
  • Page 27 Power Supply 2.9.3.1 Mars1417V supports both DC Power and Battery package input. Infrared Device 2.9.3.2 Mars1417V does not include Infrared Device. User can choose by them; however some basic requirements should be followed. iRay Technology Co. Ltd.
  • Page 28: Product Specification

    Max. 15W Dimension (L × W × H) 460 x 384 x 15.2 mm Weight (with one battery) Mars1417V-PSI: 3.5 kg without battery, 3.72 kg with battery Mars1417V-TSI: 3.6 kg without battery, 3.82 kg with battery Image Transfer Wireless : IEEE802.11a/b/g/n Data Transmission Rate (Wireless) 802.11b : Max.
  • Page 29 Discharged End Voltage 8.25V Charging Method CC-CV Operating Temperature Charge 0℃-+45℃, Discharge-10℃-+40℃ 1 month-20℃-+50℃ 3 month -20℃-+40℃ Storage Temperature 6 month -20℃-+20℃ Relative Humidity 65± 20% Dimension (L × W × H) 210 x 115 x 7.5 mm iRay Technology Co. Ltd.
  • Page 30 Specifications DC Power 24V(DC), 0.75A Battery Package 10.8V(DC),1.5A 2.10.5 Infrared Device (Optional) Mars1417V does not include Infrared Device. User can choose by themself, however some basic requirements should be followed. Item Specifications IRDA Protocol Compliant with IrDA V1.0 and V1.1 Compliant with USB V2.0 and V1.1...
  • Page 31 2. General Description Data Rate Max. 4Mbps 2.10.6 AP Router (Optional) Mars1417V do not include AP Router. Users can choose AP Router as they wish, however specification below is a requirement. Item Specifications Wireless Standard IEEE 802.11 a/b/g/n Frequency Range 2.412 ~ 2.4835 GHz and 5.15 ~ 5.85 GHz...
  • Page 32 Mars1417V Digital Flat Panel Detector User Manual 2.10.8 Recommended Application Condition Item Description Windows XP/7 32/64bit Operating System Intel Core i7 3.6G 4G DDR3 Memory 640 G Hard Disk Intel Pro EXP9301CT PRO LAN Card Gigabit Network Adapter with PCIe interface 2.10.9 Mechanical Outlines...
  • Page 33 2. General Description 2.10.10 Use Environment Temperature Atmospheric Temperature Humidity Pressure Change change Pressure iRay Technology Co. Ltd.
  • Page 34 <10kp/min 10~35℃ Operating <1k/min 30%~80% RH 700~1060hPa (1kp=1.0197E-5Pa) <10kp/min -20~55℃ Storage <1k/min 10%~95% RH 700~1060hPa (1kp=1.0197E-5Pa) The Mars1417V serial detectors shall operate at an altitude specified not more than 3000m, the environment is only for detector. iRay Technology Co. Ltd.
  • Page 35 3 Installation 3. Installation Battery Charger Installation ........37 Software Installation ..........38 Panel Infrastructure ..........38 iRay Technology Co. Ltd...
  • Page 36: Panel Installation

    3 Panel Installation 3.1.1 Attach Battery Pack Mars1417V can be powered by both battery package and DC power. Once battery package is inserted or DC power is on, Panel would be activated immediately. If none of battery and DC power is on, Mars1417V would power off. Please see below for battery installation.
  • Page 37 If panel is powered on, user can press the button for 4 seconds to shut down. On the other hand, it can also be used as reset inner control IC when button is active for 8s. After booting up, user can check the status LED indicator. iRay Technology Co. Ltd.
  • Page 38 Mars1417V Digital Flat Panel Detector User Manual Operating Status Power Indicator Lighting Status Battery Operating DC Input Capacity Power OFF ≤10% Orange ON Power ON  Battery capacity >10%, no DC Green ON Power ON input  DC input , no Battery Orange Fast ≤10%...
  • Page 39: Battery Charger Installation

     Green ON Data Transmission  Orange blinking Fatal Error  Orange ON Initialization 3.2 Battery Charger Installation Operation Figure Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. iRay Technology Co. Ltd.
  • Page 40: Software Installation

    3.4 Panel Infrastructure Mars1417V supports two connection modes as follows, the IP address and other information mentioned below is as the example, user should configure the connection with the specific requirement.
  • Page 41 3. Installation Cable to Workstation, Connect another end to LAN port of External wireless AP Open local network management interface Open local network configuration iRay Technology Co. Ltd.
  • Page 42 Mars1417V Digital Flat Panel Detector User Manual open IPV4 setting Select “Obtain an IP address automatically” IP setting Network mask setting Open browser and type 192.168.1.1 Log into external wireless AP iRay Technology Co. Ltd.
  • Page 43 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] Configure 5GHz wireless network SSID: NETGEAR_BIG_50 Security: WPA2-PSK Password: 12345678 Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] iRay Technology Co. Ltd.
  • Page 44 Mars1417V Digital Flat Panel Detector User Manual LAN setup Configure LAN IP address IP address: 192.168.8.1 Subnet Mask: 255.255.255.0 External wireless AP reboot Apply above settings and reboot your wireless router. Recover local network IPv4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0...
  • Page 45 It is necessary to finish 3.4.1.1, then proceed to the steps below. Connect panel to Workstation with Ethernet Cable like 3.4.1 Click “Detector” Click”Read Config” Choose Client mode Click “Add” Type SSID and Password Click”Apply” iRay Technology Co. Ltd.
  • Page 46 Mars1417V Digital Flat Panel Detector User Manual Choose SSID and select(There will be √ occurred)” Click ”write config” to save parameters. Turn on wireless router. wired connection Make sure there are between router and work station and IP 192.168.8.188. Click”Read wifi Status” to check...
  • Page 47 3. Installation Start IrDARegister.exe Click “ ” to open wifi setting Change SSID and password, do not select AP mode Click “Apply” iRay Technology Co. Ltd.
  • Page 48 Mars1417V Digital Flat Panel Detector User Manual Click” ” Click”Start” Point Infrared device to detector’s infrared interface iRay Technology Co. Ltd.
  • Page 49 Either Wired cable or Infrared device can be used to configure panel wireless AP mode. The wired connection should be used by the service operator only. a.To start wired cable configuration, users should finish 3.4.1.1, then proceed to the steps below. Connect panel to Workstation with Ethernet Cable like 3.4.1 iRay Technology Co. Ltd.
  • Page 50 Mars1417V Digital Flat Panel Detector User Manual Click “Detector” Select ”wifi” Choose AP mode iRay Technology Co. Ltd.
  • Page 51 Click “Read Config” to get default setting. Change SSID and password setting , make sure SSID is different from other already exist; Change channels and frequency setting Click ”Channel” and choose a clean frequency and channel iRay Technology Co. Ltd.
  • Page 52 Mars1417V Digital Flat Panel Detector User Manual Click ”write config” Do not remove wired cable until FPD status from Busy become Ready Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time.
  • Page 53 3. Installation Start IrDARegister.exe Click “ ” to open wifi setting iRay Technology Co. Ltd.
  • Page 54 Mars1417V Digital Flat Panel Detector User Manual Select “AP mode” Change SSID and password and other parameter, make sure SSID is different from other already exist; Click “Apply” Click” ” iRay Technology Co. Ltd.
  • Page 55 3. Installation Click”Start” Do not click”Exit” until succeed Configuration of external wireless card iRay Technology Co. Ltd.
  • Page 56 Mars1417V Digital Flat Panel Detector User Manual Open local wireless signal list Select SSID which belongs to detectors; Input password and log into system Open wireless card configuration iRay Technology Co. Ltd.
  • Page 57 3. Installation open IPV4 setting IP setting IP address: 192.168.8.188 Network mask setting Subnet mask: 255.255.255.0 Open SDK and choose product start connection iRay Technology Co. Ltd.
  • Page 58 Mars1417V Digital Flat Panel Detector User Manual 4. Operation Main Operation ............. 57 Connection Build ..........65 Panel Configuration ..........65 Correction and Calibration Template Generation . 67 Image Check and upload .......... 71 Defect Template Check and Modification ....73 Correction and Calibration Management ....
  • Page 59: Operation

    4. Operation 4 Operation Mars1417V provides SDK for user to integrate panel into their DR system. Additionally, it also provides an application for demonstration, i.e. iDetector. User can use iDetector to control panel without DR system. 4.1 Main Operation To Acquire X ray image is the main operation of Mars1417V. Most importantly, panel should build synchronization with X ray generator.Mars1417V is born with four ways to acquire x ray...
  • Page 60 Mars1417V Digital Flat Panel Detector User Manual Work flow 4.1.1.2 Click “Prep” Panel preparation,Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X ray at any time. However the longer time you wait. The worse image would be. So please shoot once x ray generator is ready.
  • Page 61 Workstation is a host PC device installed with IDetector and SDK. Chapter 3 has described how to establish connection between panels and workstation. In inner mode, workstation does not control x ray generator. Users would decide when to shoot x ray. iRay Technology Co. Ltd.
  • Page 62 Mars1417V Digital Flat Panel Detector User Manual Work Flow 4.1.2.2 Click “Prepare” Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X ray in exposure window. However the longer time user waits. the worse image would be. So please shoot once x ray generator is ready.
  • Page 63 10. Panel completes image acquisition and begins to send data to Workstation. 11. Workstation starts receiving image data from panel. 12. Workstation receives all image data from panel which are after calibration is Hardware calibration is on. 4.1.3 Prep Mode Block Diagram 4.1.3.1 Syncbox Workstation(Prep) Tube iRay Technology Co. Ltd.
  • Page 64 Mars1417V Digital Flat Panel Detector User Manual Work Flow 4.1.3.2 Click “Acq2” or push Hand-switch Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X ray in exposure window (for click “Acq2” button). Or the exposure flow will start when use hand-switch.
  • Page 65 Workstation is a host PC device installed with iDetector and SDK. Chapter 3 has described how to establish connection between panel and Workstation. In FreeSync mode, User doesn’t interact with Workstation. After shooting, images would be shown on screen immediately. iRay Technology Co. Ltd.
  • Page 66 Mars1417V Digital Flat Panel Detector User Manual Work Flow 4.1.4.2 Check SDK to make sure panel is ready Shoot X ray X ray sensor in panel triggers panel to stop flushing the panel After fixed time, panel starts image acquisition...
  • Page 67: Connection Build

    If there is no command transmission between panel and Workstation over 5 minutes, panel releases access authority. 4.3 Panel Configuration Choose iDetector menu related modules iRay Technology Co. Ltd.
  • Page 68 Mars1417V Digital Flat Panel Detector User Manual Acquire module related setting, such as loading correction and calibration template, acquiring images SDK module related setting, such as IP address Detector module related setting, such as trigger module, wireless signal Calibrate module related setting, such as...
  • Page 69: Correction And Calibration Template Generation

    On the other hand, it is also recommended to do the correction and calibration in each 6 months. 4.4.1 Pre-offset Template Generation If panel is configured to do Pre-offset correction, Pre-offset Template is necessary. See below Choose “PreOffset”, and click “Start Generate Templates” iRay Technology Co. Ltd.
  • Page 70 Mars1417V Digital Flat Panel Detector User Manual click “Start the journey of Calibration” And waiting for the finish 4.4.2 Gain Calibration Template Generation Gain Calibration Template Generation 4.4.2.1 Before Gain template generating, make sure SID1.2m, no copper is required, the GUI of the software maybe different with the below figures.
  • Page 71 Start exposure, get the light image, and click “NEXT” If the warning occurs, it means the user should adjust the dose and re- exposure Click “NEXT”, and get five images After getting five images, click “NEXT” to generate gain template iRay Technology Co. Ltd.
  • Page 72 Mars1417V Digital Flat Panel Detector User Manual Waiting for finish of gain template generating Notes:1 please use software post offset correction. Defect Correction Template Generation 4.4.2.2 Before Defect template generating, make sure SID1.2m, no copper is required, the GUI of software maybe different with the below figures.
  • Page 73: . 67 Image Check And Upload

    “OPEN” provides two features for image check and uploading. Local Image Check, Panel Image Upload. Local Image Check defines function to check image saved in Workstation. Panel Image Upload defines function to upload images stored in panel. iRay Technology Co. Ltd.
  • Page 74 Mars1417V Digital Flat Panel Detector User Manual 4.5.1 Local Image Check Click “Local File” button in “Local File” UI, choose the specified file Choose images stored in Workstation, images would be shown on screen 4.5.2 Panel Image Upload Make sure firewall is closed Panel Image is uploaded as following.
  • Page 75: Defect Template Check And Modification

    If defect template has updates, user could add and delete defect pixel or defect lines by modifying defect template opened. 4.6.1 Defect Template Check Click “LoadFile” on “LocalFile” page iRay Technology Co. Ltd.
  • Page 76 Mars1417V Digital Flat Panel Detector User Manual Choose the specified defect template, and click “Open” The defect template will showed on the UI 4.6.2 Defect Template Modification Open the specified defect template iRay Technology Co. Ltd.
  • Page 77 Click “Save” It is similar to manage the defect pixel, If user need to add the defect line, type the coordinate of the line and click “Add” If the information needs to be deleted, click “Delete” iRay Technology Co. Ltd.
  • Page 78: Correction And Calibration Management

    Mars1417V Digital Flat Panel Detector User Manual 4.7 Correction and Calibration Management 4.7.1 Correction and Calibration template synchronization Panel supports correction and calibration template storage. So template in panel could be uploaded to Workstation, and template in Workstation could also be downloaded to panel.
  • Page 79 Hardware Correction and Calibration. User can set the calibration method on “Detector” page Choose “HWPostOffset”, “HWGain”, “HWDefect”, the hardware-based calibration is on If the detector is set as the PrepMode and Acq2, the Offset should be set as HWPreOffset iRay Technology Co. Ltd.
  • Page 80: Firmware Update

    Mars1417V Digital Flat Panel Detector User Manual Choose “SWPostOffset”, “SWGain”, “SWDefect”, the software-based calibration is on If the detector is set as the PrepMode and Acq2, the Offset should be set as HWPreOffset 4.8 Firmware Update Panel supports updating firmware with IDetector, also allows the use of the Web way to upgrade the firmware, if a user needs to update the firmware, please complete the following steps.
  • Page 81 Click “ CPU”; Select “ST STM32L151C8”; Click “Target->Connect” Click “Target-> Erase” Click “Target->Program” Click “Target->Start Application” Note:1. Make sure panel is powered up. If current MCU version is 2.5.2.*, Please refer to 4.10.2 and 4.10.3 for upgrading. iRay Technology Co. Ltd.
  • Page 82 Mars1417V Digital Flat Panel Detector User Manual 4.8.2 Firmware Update After connecting the detector, click the “Parameters” page in “Detector” User can enter the upgrade UI by clicking “Upgrade Firmeare” button The dialog box shows the version of the current firmware Click “Browse”...
  • Page 83: Short Cut

    Drag the left mouse button, drag the image displayed.  Lateral-drag the right mouse button to adjust the window width, and vertical-drag the right mouse button to adjust the window level.  F3 Key: Quickly adjust the image window width and window level. iRay Technology Co. Ltd.
  • Page 84: Software

    Mars1417V Digital Flat Panel Detector User Manual 4.10 Software 4.10.1 Main GUI iRay provides test tools, such as iDetector for testing the basic performance of detector. It can connect the detector, acquire image, image correct and calibrate. Function description of regions and buttons within the main window as follows:...
  • Page 85 Management for syncbox 4.10.2 Message Box 4.10.2.1 Status Box Status box defines the current status of panel. Serial Number of the detector Status Status of the detector, busy or ready Task The current task being executed iRay Technology Co. Ltd.
  • Page 86 Mars1417V Digital Flat Panel Detector User Manual Message Information Remaining power of the battery, showed as percentage 4.10.2.2 Progress Bar Progress Bar defines as following. If progress bar is Green when shooting X ray, image quality is acceptable, otherwise image quality would degrade.
  • Page 87 Type number of the detector Product No Sub Product No Sub-type of the detector Serial No Serial number of the panel Main Version Version of the firmware of Main FPGA Read Version Version of the firmware of Read FPGA iRay Technology Co. Ltd.
  • Page 88 Mars1417V Digital Flat Panel Detector User Manual MCU Version Version of the firmware of MCU Arm Version Version of the App of ARM Kernel Version Version of the Kernel of ARM Prep CapMode Sub work-flow for Prep Mode, can be configured as...
  • Page 89 IP Address of local workstation Host Port Port of local workstation Ftp Download Host FTP download server IP, keep the same as Host IP Ftp Download Host FTP download server Port, keep the same as Host iRay Technology Co. Ltd.
  • Page 90 Mars1417V Digital Flat Panel Detector User Manual Port Port Ftp Upload Host IP FTP upoload server IP, keep the same as Host IP Ftp Upload Host Port FTP upload server Port, keep the same as Host Port Clr Acq Delay Time...
  • Page 91 AP Mode AP Mode Set panel in AP mode or Client mode Configuration SSID Wireless AP SSID when panel in AP mode iRay Technology Co. Ltd.
  • Page 92: List Of The Hazardous Situations Resulting From A Failure Of The It-Network

    Mars1417V Digital Flat Panel Detector User Manual Wireless AP Key when panel in AP mode Security Wireless AP Security way when panel in AP mode Frequency Wireless AP Frequency(2.4GHz and 5GHz) when panel in AP mode Country Wireless AP Country Code when panel in AP...
  • Page 93 5. Regulatory Information 5. Regulatory Information Medical equipment safety standards ....92 The compliance for each EMISSIONS and IMMUNITY standard or test specified by IEC60601-1-2 standard ........93 Radio Frequency Compliance Information ... 97 Battery Safety Standards........98 iRay Technology Co. Ltd.
  • Page 94: Regulatory Information

    Mars1417V Digital Flat Panel Detector User Manual 5 Regulatory Information 5.1 Medical equipment safety standards  Medical equipment classification Type of protection against electrical shock External electrical power source equipment Class I Equipment (medical approved adaptor) Internal electrical power source equipment (battery)
  • Page 95: The Compliance For Each Emissions And Immunity Standard Or Test Specified By Iec60601-1-2 Standard

    Group 1, Class B IEC 61000-3-2 Harmonic distortion Professional healthcare facility environment Class A Voltage fluctuations and IEC 61000-3-3 Professional healthcare facility environment flicker Compliance EMS Compliance Table Enclosure Port Phenomenon Basic EMC standard Immunity test levels iRay Technology Co. Ltd.
  • Page 96 Mars1417V Digital Flat Panel Detector User Manual Professional healthcare facility environment ± 8 kV contact ElectrostaticDischarge IEC 61000-4-2 ± 2kV, ± 4kV, ± 8kV, ± 15kV air 3V/m Radiated RF EM field IEC 61000-4-3 80MHz-2.7GHz 80% AM at 1kHz Proximity fields from Refer to table “Proximity fields from RF wireless...
  • Page 97 100kHz repetition frequency Conducted 3V, 0.15MHz-80MHz disturbances induced IEC 61000-4-6 6V in ISM bands between 0.15MHz and 80MHz by RF fields 80%AM at 1kHz Signal input/output parts Port Phenomenon Basic EMC standard Immunity test levels iRay Technology Co. Ltd.
  • Page 98 The use of accessories, transmitters and cables other than those specified by this User Manual, with the exception of accessories and cables sold by iRay of Mars1417V as replacement parts for inner components, may result in increased emission or decreased immunity.
  • Page 99: Radio Frequency Compliance Information

    Technology Co. Ltd.
  • Page 100: Battery Safety Standards

    Mars1417V Digital Flat Panel Detector User Manual 5.4 Battery Safety Standards Standards Description UL1642 Component Recognition on the Secondary Li-ion cell UL 2054 Household and commercial Batteries IEC 62133:2012 Secondary cells and batteries containing alkaline or other non-acid electrolytes UN38.3...
  • Page 101 6 Trouble shooting 6. Trouble shooting Trouble Shooting ................101 iRay Technology Co. Ltd...
  • Page 102: Trouble Shooting

    Mars1417V Digital Flat Panel Detector User Manua 6 Trouble Shooting Please refer to service manual. If the problem persists, turn off the panel and contact iRay service department ( ). We would provide the best service. service@iraychina.com iRay Technology Co. Ltd...
  • Page 103: Product Lifetime 103

    7. Service Information 7. Service Information 7.1 Product Lifetime ................103 7.2 Regular Inspection and Maintenance ..........103 7.3 Repair ....................103 7.4 Replacement Parts Support ............103 iRay Technology Co. Ltd.
  • Page 104 Mars1417V Digital Flat Panel Detector User Manual 7 Service Information 7.1 Product Lifetime The estimated product lifetime is up to 5 years under appropriate regular inspection and maintenance.(battery 5 years) 7.2 Regular Inspection and Maintenance In order to ensure the safety of patients and operator, to maintain the performance and reliability of the panel, be sure to perform regular inspection at least once a year.
  • Page 105 Appendix Appendix APPENDIX ..........................103 iRay Technology Co. Ltd.
  • Page 106 Mars1417V Digital Flat Panel Detector User Manual Appendix A Information of Manufactures COMPANY: iRay Technology Co. Ltd. ADDRESS: Rm202, Building 9, No. 590, Ruiqing Rd, Pudong, Shanghai. ZIPCODE: 201201 TELEPHONE: +86-21-50720560 FAX: +86-21-50720561 HOMEPAGE: http://www.iraychina.com SERVICE: SERVICE DEPARTMENT of iRay...
  • Page 107 Appendix Appendix B Information of Medical Device Directive European Representative IRAY EUROPE GMBH ADDRESS: IN DEN DORFWIESEN 14, 71720 OBERSTENFELD GERMANY TEL: +49-7062-977 88 00 FAX: +49-7062-976 0571 ZIP CODE: / WEBSITE: WWW.IRAYEUROPE.COM iRay Technology Co. Ltd.

This manual is also suitable for:

Mars1417v2Mars1417v-psiMars1417v-tsi

Table of Contents