Summary of Contents for iRay Technology Mars1717VS
Page 1
Wireless Digital Flat Panel Detector Mars1717VS User Manual Document Version: A0 Document ID: 119-201-01 Release Date: 2019.09.16 Before operating, please read this user manual and pay attention to all safety precautions. Please ensure that this user's manual is properly maintained so that it can be accessed at any time ( reserve ).
Page 3
—Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. —Consult the dealer or an experienced radio/TV technician for help. About SAR This equipment complies with FCC exposure limits set forth for an uncontrolled environment. iRay Technology Co., Ltd.
To Customers Congratulations on your purchase of the Fixed Digital Flat Panel (hereinafter referred to as Mars1717VS) which is manufactured by iRay Technology Co.Ltd. (Hereinafter referred to as iRay). At iRay, we strive to not only make the world-class products that deliver the best value possible to our customers but also offer the highest quality of service and customer care.
Page 5
No part of this publication may be reproduced in any form or by any means without the written permission of iRay. The information contained herein is designed only for use with iRay Mars1717VS. Trademarks The iRay name and iRay logo are registered trademarks of iRay Technology Co.Ltd. iRay Technology Co., Ltd.
Page 6
Mars1717VS Digital Flat Panel Detector User Manual Symbols and Conventions The following symbols and conventions are used throughout the user guide. This symbol is used to identify conditions under which improper use of the product may cause death or serious personal injury.
Page 7
Safety Signs: please refer to the user guide for safety instructions. Safety Signs:Dangerous Voltage. Handled with care. This symbol is used to indicate the operational temperature limits. This symbol indicates the product radiates wireless signal. iRay Technology Co., Ltd.
Page 8
Mars1717VS Digital Flat Panel Detector User Manual Package symbol, fragile. Package symbol, keep away from sunlight. Package symbol, keep dry. Package symbol, keep the equipment up right. Package symbol, do not roll the transportation package. Type-B applied part Package symbol, this symbol is used to indicate stacking limit number.
Mars1717VS Digital Flat Panel Detector User Manual Contents TO CUSTOMERS.......................... 2 CONTENTS ..........................7 SAFETY ..........................9 1.1 Safety Precautions ....................... 10 1.2 Notes for Using of FPD ....................... 14 1.3 Notes for Using of Battery ....................14 2. GENERAL DESCRIPTION ..................... 16 2.1 Scope ............................
Page 10
8.3 Regular Inspection and Maintenance ..................74 8.4 Repair ............................ 74 8.5 Replacement Parts Support ....................75 9. APPENDIX ..........................76 9.1 Appendix A Information of Manufactures ................77 9.2 Appendix B Information of Medical Device Directive European Representative ....77 iRay Technology Co., Ltd..
Mars1717VS Digital Flat Panel Detector User Manual 1. Safety 1.1 Safety Precautions ........................ 10 1.2 Notes for Using of FPD ....................... 14 1.3 Notes for Using of Battery ....................14 iRay Technology Co., Ltd.
Mars1717VS Digital Flat Panel Detector User Manual 1.1 Safety Precautions Follow these safeguards and properly use the equipment to prevent injury and damage to any equipment/data. WARNING Do not use or store the equipment near flammable Installation and chemicals such as alcohol, thinner, benzene, etc.
Page 13
For safety reasons, be sure to turn OFF the power to each piece of equipment when performing inspections indicated in this manual. Otherwise, electric shocks may occur. iRay Technology Co., Ltd.
Page 14
Mars1717VS Digital Flat Panel Detector User Manual CAUTION Do not install the equipment in any of the locations Installation and listed below. Doing so may result in failure, environment of malfunction, equipment falling, fire or injury. Close to facilities where water is used...
Page 15
Please charge battery with charger following IEC60601- 1 & IEC62133 Standards provide by us Do not mix battery with ones not provided by our company Do not charge battery with broken charger. iRay Technology Co., Ltd.
Be sure to check the equipment daily and confirm that it works properly. Be sure there be a battery installing on the Mars1717VS to avoid the power off suddenly Sudden heating of the room in cold areas will cause condensation to form on the equipment.
Page 17
If battery remaining capacity is lower than 20%, delivery is not allowed, or it is possible to be over discharge. Battery storage and working environment should strictly follow specification. If there is any objection, there is possibility to damage performance If battery is not used in detector, please detach it. iRay Technology Co., Ltd.
2. General Description Mars1717VS is a cassette-size wireless X-ray flat panel detector based on amorphous silicon thin-film transistor technologies. It is developed to provide the good quality of radiographic image, which contains an active matrix of 3070×3070 with 139um pixel pitch.
Mars1717V Digital Flat Panel Detector User Manual According to the Mars1717VS series INTENDED USE and the result of risk management, image acquisition and data transmission are defined as ESSENTIAL PERFORMANCE. Getting dark image proves that ESSENTIAL PERFORMANCE does not influence INTENDED USE.
2. General Description 2.6 Product Components Mars1717VS comes with battery package. Once powered on, it would build a connection with Workstation through Ethernet cable (only for service) or Wireless connection. Item Description 1pcs Detector Main Unit 1pcs Battery Battery pack...
Page 22
Mars1717V Digital Flat Panel Detector User Manual Ethernet Cable 1pcs (Only for service) Ethernet Adapter 1pcs Battery Charger 1pcs iRay Technology Co., Ltd..
2. General Description 2.7 Components Description And Specification 2.7.1 Detector External Signals Input External Power Input Item Description iRay Technology Co., Ltd.
Page 24
3.6 Lp/mm without phantom or grid Image Acquisition Time (Wireless) Preview: 2.5 sec. Client mode(5G) Processed: 7 sec. Cycle Time Min. 9s Power Consumption Max. 20W (Without Handle) Dimension (L × W × H) 461 x 461 x 15.7 mm iRay Technology Co., Ltd..
Battery Interface 8 Pin Battery connector Capacity Indicator The indicator definition is as follow Power Indicator The indicator definition is as follow Hand Pull Position The limit ball plug DC Jack 24V DC input Dimension and Specification iRay Technology Co., Ltd..
Page 29
A indicator on Battery charging abnormal B and C alternately blinking Two or more battery charging at the same time is prohibited, if inserted at the same time, the charger will automatically stop working. iRay Technology Co., Ltd.
<10kp/min 10%~90% Operating 5~35℃ <1k/min 700~1060hPa (1kp=1.0197E- 5Pa) <10kp/min 10%~90% Storage -10~55℃ <1k/min 700~1060hPa (1kp=1.0197E- 5Pa) The Mars1717VS serial detectors shall operate at an altitude specified not more than 3000m, the environment is only for detector. iRay Technology Co., Ltd..
Mars1717VS can be powered by both battery package and DC power. Once battery package is inserted or DC power is on, Panel would be activated immediately. If none of battery and DC power is on, Mars1717VS would power off. Please see below for battery installation.
Orange (blinking) Green(blinking) The battery is charging Green WIFI connecting is normal Link Orange WIFI link is lost Green SDK is OK SDK is disconnect or firmware update Orange Status Green(blinking) Exposure indication Orange (blinking) FPD Error iRay Technology Co., Ltd.
Mars1717V Digital Flat Panel Detector User Manual 3.2 Battery Charger Installation Operation Figure Unload Battery from battery charger. Insert battery into battery charger. Note the interface position as figure. Press the battery to the bottom of battery compartment. iRay Technology Co., Ltd..
4.7.1 HomePage ......................... 46 4.7.2 Acquire Page ......................47 4.7.3 Detector Page ......................48 4.7.4 Calibrate Page ......................49 4.7.5 Local Page ......................... 49 4.8 List of the HAZARDOUS SITUATIONS resulting from a failure of the IT-NETWORK ..50 iRay Technology Co., Ltd.
3. For Windows XP, full path should be used in file “bind.txt”. 4.3 Connection Mode Mars1717VS supports one connection modes as follows, the IP address and other information mentioned below is as the example, user should configure the connection with the specific requirement.
4. Software Setup 4.4 Wired Connection Setup (Service Only) Select wired network adapter that connected to the detector. Right click the network adapter. Then select properties. iRay Technology Co., Ltd.
Page 38
Mars1717V Digital Flat Panel Detector User Manual Double click IPV4 item Default IP settings: IP address: 192.168.8.188 Subnet mask: 255.255.255.0 The IP address should be identical with Cfg_HostIP item in work_dir\Mar1717VS \config.ini file. iRay Technology Co., Ltd..
Set up the Wireless AP IP address 192.168.8.188 Subnet Mask 255.255.255.0 The setting process will be viable depends on AP model Here shows the Netgear Wireless Router setup Open local network management interface iRay Technology Co., Ltd.
Page 40
Mars1717V Digital Flat Panel Detector User Manual Right click the network adapter, select properties and entered the Local connection Properties window as shown left. Double click IPV4 item Select “Obtain address automatically” iRay Technology Co., Ltd..
Page 41
Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] SSID: NETGEAR_BIG_50 Security: WPA2-PSK Configure 5GHz wireless Password: 12345678 network Channel: [Please check the current Wi-Fi environment, and choose a relatively clean channel] iRay Technology Co., Ltd.
Page 42
IP address: 192.168.8.1 Subnet Mask: 255.255.255.0 The AP setup is done 3. Workstation IP setup After AP setup done, the user can setup the Workstation IP address Open local network management interface iRay Technology Co., Ltd..
Page 43
Right click the network adapter, select properties and entered the Local connection Properties window as shown left. Double click IPV4 item Set the Default IP as follows: IP address: 192.168.8.188 Subnet mask: 255.255.255.0 iRay Technology Co., Ltd.
Page 44
Either Wired Cable or AP mode can be used to configure detector To start configuration with wired cable. It is necessary to finish 4.4, then proceed to the steps below. Connect panel to Workstation like 4.4 iRay Technology Co., Ltd..
Page 45
Click “Read Config” Choose Client mode Click “Add” Type SSID and Password Click “Apply” Choose SSID and select (There will be √ occurred) Click “write config” to save parameters. iRay Technology Co., Ltd.
Page 46
Click “Read WIFI Status” to check wireless transmission status, numerical value occurred means the link is up and available. Since we have chosen default SSID and password, it would connect to wireless AP immediately after powered on next time. iRay Technology Co., Ltd..
Acquire image, select correction mode, save image and process image config.ini setting, log level setting Detector Configurate parameters for detector. Calibrate Generate calibration files and manage the calibration files Local File Open and view local images. iRay Technology Co., Ltd.
Click this button to disconnect the selected detector. Add work directory Remove Remove work directory Syncbox Open Syncbox configuration window (Optional device) The version of the SDK is displayed here, and the information will vary depending on the SDK version. iRay Technology Co., Ltd..
Item Description SN number of current connected detectors State Detectors state, e.g. busy, ready Task the current task of detector Message feedback information of command, e.g. succeed, failed Functions in this Page. iRay Technology Co., Ltd.
ROI areas. WW/WL Auto adjust WW/WL based on selected area by right button of mouse. Image List Show thumbnails 4.7.3 Detector Page In Detector page, Detector Parameters, Sensor, Wifi and Images tab could be set. iRay Technology Co., Ltd..
Users can also refers to chapter 5.2 for panel Correlation and Calibration tutorial. 4.7.5 Local Page The idetector Software includes a local images display tool that allows users to look up local images. Please refer to 903-341-14_iDetector_UserManual_EN_A4 for specific operation methods. iRay Technology Co., Ltd.
The operating system is not compatibility; b) Change or upgrade the software failed; c) The compatibility of the interface; d) The data transfer protocol error; e) The inconsistent of interface or format leads to data distortion; The data output failed; iRay Technology Co., Ltd..
Mars1717V Digital Flat Panel Detector User Manual Mars1717VS provides SDK for user to integrate panel into their DR system. Additionally, it also provides an application for demonstration, i.e. iDetector. User can use iDetector to control panel without DR system. 5.1 Main Operation To Acquire X-ray image is the main operation of Mars1717VS.
Acquire images in the selected mode To Acquire X-ray image is the main operation of Mars1717VS. Most importantly, detector should build synchronization with X-ray generator. Mars1717VS has one synchronization mode to acquire X-ray image, which is Software Mode.
Panel preparation, Wait until the warning message change from “Exposure Prohibit” to “Exposure Enable” Shoot X-ray at any time. However the longer time you wait. The worse image would be. So please shoot once X-ray generator is ready. Wait for image uploaded iRay Technology Co., Ltd..
Page 57
5. User triggers X-ray generator to initialize and do anode rotation to prepare for X-ray shooting. 6. X-ray generator finishes preparation for X-ray shooting and reminds user to shoot. 7. X-ray generator starts releasing X-ray. 8. X-ray generator finishes x-ray shooting. 9. Time out, panel acquires data. iRay Technology Co., Ltd.
Page 58
If Hardware Post offset and Hardware calibration is selected, image got would be preview image. After step11, panel would do another dark image acquisition. With both light image and dark image, panel completes all the correction and calibration process. Finally, panel uploads processed image to workstation. iRay Technology Co., Ltd..
Click “UpdateHWPreOffset” 5.2.2 Gain Calibration Template Generation On Gain template generating page, there are 12 images that need to be got. The operation process is as follows: 1) Click “start” button; 2) Click “PREP”, and start exposure; iRay Technology Co., Ltd..
“OPEN” provides two features for image check and uploading. Local Image Check, Panel Image Upload. Local Image Check defines function to check image saved in Workstation. Panel Image Upload defines function to upload images stored in panel. iRay Technology Co., Ltd.
Page 62
Select correct size to open image files. If the file is not correct user will get an error message. Mars1717VS image size: 3070*3070 This page provides ROI tool, which can see the AVG, SNR, and other properties of the choosen image area by right mouse button.
After connecting the detector, click the “Parameters” page in “Detector” User can enter the upgrade UI by clicking “Upgrade Firmware” button iRay Technology Co., Ltd.
Page 64
.ifirm After choosing the file, the lower dialog box shows the version of the new firmware, user should check the information and click “Start Upgrade” After the upgrade process is finished, power-cycle the detector iRay Technology Co., Ltd..
CORR. 2 (2007) + AM1 (2012) performance Medical electrical equipment – Part 1: General EN 60601- requirements for basic safety and essential 1:2006+A11:2011+A1:2013+A12:2014 performance Medical electrical equipment –Part 1: General BS EN 60601-1:2006+A11:2011 requirements for basic safety and essential performance iRay Technology Co., Ltd..
Page 67
Safety requirements for portable sealed secondary cells, and for batteries made from them, for use in portable applications Medical electrical equipment – Characteristics of EN 62220-1:2004 digital X-ray imaging devices–Part 1: Determination of the detective quantum efficiency iRay Technology Co., Ltd.
Page 70
Important information regarding Electromagnetic Compatibility (EMC) Mars1717VS requires special precautions regarding EMC and needs to be installed only by iRay or authorized personnel and put into service according to EMC information provided in the user manual. Mars1717VS in use may be susceptible to electromagnetic interference from portable and mobile RF communications such as mobile (cellular) telephones.
The use of accessories, transmitters and cables other than those specified by this User Manual, with the exception of accessories and cables sold by iRay of Mars1717VS as replacement parts for inner components, may result in increased emission or decreased immunity.
Consult the distributor or an experienced radio/TV technician for help. 6.4 Battery Safety Standards Standards Description IEC 62133:2012 Secondary cells and batteries containing alkaline or other non- acid electrolytes UN38.3 United Nations Recommendations on the Transport of dangerous goods Manual of tests and Criteria ST/SG/AC.10/11/Rev.5/Amend.1&Amend.2 iRay Technology Co., Ltd..
Mars1717V Digital Flat Panel Detector User Manual 7. Trouble Shooting TROUBLE SHOOTING ....................... 71 iRay Technology Co., Ltd.
Page 74
6. Regulatory Information Please refer to service manual. If the problem persists, turn off the panel and contact iRay service department (service@iraygroup.com). We would provide the best service. iRay Technology Co., Ltd..
Mars1717V Digital Flat Panel Detector User Manual 8. Service Information 8.1 Product Lifetime ........................74 8.2 Regular Inspection and Maintenance ..................74 8.3 Repair ............................ 74 8.4 Replacement Parts Support ....................75 iRay Technology Co., Ltd.
If problem cannot be solved, contact your sales representative or local iRay dealer for repairs. Please refer to the label and provide the following information: Product Name: Series Number: Description of Problem: as clearly as possible. iRay Technology Co., Ltd.
Appendix 8.5 Replacement Parts Support Main parts (parts required to maintain the function of the product) of this product will be stocked for 5 years after discontinuance of production for repairing. iRay Technology Co., Ltd.
8. Service Information 9. Appendix Appendix A Information of Manufactures ..................77 Appendix B Information of Medical Device Directive European Representative ......77 iRay Technology Co., Ltd..
Mars1717V Digital Flat Panel Detector User Manual 9.1 Appendix A Information of Manufactures COMPANY: iRay Technology Taicang Ltd. ADDRESS: No.33 Xinggang Road, Taicang Port Economic and Technological Development Zone, Jiangsu, China ZIP CODE: 215434 TELEPHONE: +86 0512-53690872 FAX: +86 0512-53690872 WWW.IRAYGROUP.COM...
Page 80
RF exposure in usage against the body with no separation. Although the SAR is determined at the highest certified power level, the actual SAR level of the device while operating can be well below the maximum value. iRay Technology Co., Ltd.
Page 81
This EUT is in compliance with SAR for general population/uncontrolled exposure limits in IC RSS-102 and had been tested in accordance with the measurement methods and procedures specified in IEEE 1528 and IEC 62209. This equipment should iRay Technology Co., Ltd.
Page 82
Canada RSS 102. Ce dispositif a été testé et respecte les directives FCC et IC sur l'exposition aux radiofréquences lorsqu'il est testé en contact direct avec le corps. Pour cet appareil, la valeur SAR la plus élevée pour une utilisation près du corps est de iRay Technology Co., Ltd.
Page 83
Vous pouvez également opter pour un étui ne contenant aucun composant métallique, pour maintenir une séparation de 0 mm entre cet appareil et votre corps. Pour tout appareil contenant du métal, la conformité de l'exposition aux radiofréquences n'a pas encore été testée / certifiée de manière précise. iRay Technology Co., Ltd.
Page 84
8. Service Information End of document iRay Technology Co., Ltd.