Sleep After (SA)
This is the period of inactivity before the tool goes to Sleep.
Command
SC:SA:??
Response
OK:??
Example
Angle Display (AD)
Used to enable or disable the Angle Display.
Command
SC:AD:0
SC:AD:1
Response
OK:0
OK:1
Example
Set Sleep After- (default 120, range 0 – 300). 0 = Never (always on)
Confirm Sleep After time
(Set Angle Display OFF)
(Set Angle Display ON)
(OFF)
(ON)
25