Sending A Snug Torque + Angle Target With Final Torque Target; Confirm A Snug Torque + Angle Target With Final Torque Target - norbar NorTronic ASCII Operator's Manual

Table of Contents

Advertisement

Sending a Snug Torque + Angle with Final Torque Target
Command
TR:L:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
TR:L:
UNT0
SNG123.4
ANG30
TRQ234.5
ADT0
NUM3
Response
OK:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
Example
TR:L:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
OK:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
Remarks
You will see the following if you try to send a Target whilst NOT displaying the RUN screen.
TR:L:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
ERR:1
Confirm a Snug Torque + Angle with Final Torque Target
Command
TR:C
Response
OK:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
Example
TR:C3
OK:UNT8,SNG123.4,ANG30,TRQ234.5,ADT0,NUM3
NOTE:
The tool will clamp snug and torque targets within a range spanning the tool's current
Active From limit up to the tool's max capacity. Check the response message to ensure
the target you requested was actually set!
10
= Accept this target & switch to it
= Units (0 = N·m, 1 = dN·m, 2 = cN·m, 3 = kgf·m, 4 = kgf·cm, 5 = gf·m,
6 = lbf·ft, 7 = lbf·in, 8 = ft·lb, 9 = in·lb, 10 = oz·fin, 11 = in·oz
(in this case N·m)
= Snug Torque value (in this case, 123.4)
= Angle Target (degrees – in this case, 30)
= Final Torque Target (in this case, 234.5)
= Audit mode (0= disabled, 1= enabled)
= Number of Readings for the Target (in this case 3)
Not Enabled
(acknowledgement, followed by currently
selected target)

Advertisement

Table of Contents
loading

Table of Contents