Cable Sizes For 640-1100 V Dc (525-690 V Ac) - Danfoss VACON NXP FI9 Operating Manual

Table of Contents

Advertisement

Operating Guide | VACON® NXI Inverters FI9-FI14
Enclosure size
Type
FI12
NXI_0460 6
NXI_0502 6
NXI_0590 6
NXI_0650 6
NXI_0750 6
NXI_0820 6
FI13
NXI_0920 6
NXI_1030 6
NXI_1180 6
FI14
NXI_1500 6
NXI_1900 6
NXI_2250 6
12.4.5 Cable Sizes for 640–1100 V DC (525–690 V AC)
Table 22: Cable Sizes for 640–1100 V DC (525–690 V AC)
Enclosure size
(1)
FI9
FI10
120 | Danfoss A/S © 2019.11
Bussman aR fuse type
L
I
[A]
460
170M6305
502
170M6305
590
170M6305
650
170M6277
750
170M6277
820
170M6277
920
170M6305
1030
170M6277
1180
170M6277
1500
170M6305
1900
170M6277
2250
170M6277
Drive type
L
I
[A]
NXI_0125 6
125
NXI_0144 6
144
NXI_0170 6
170
NXI_0208 6
208
NXI_0261 6
261
NXI_0325 6
325
NXI_0385 6
385
NXI_0416 6
416
Fuse size
Fuse U
3SHT
1250
3SHT
1250
3SHT
1250
3SHT
1100
3SHT
1100
3SHT
1100
3SHT
1250
3SHT
1100
3SHT
1100
3SHT
1250
3SHT
1100
3SHT
1100
2
Supply cable Cu [mm
]
(3)
2×(1×24)
2×(1×24)
(3)
(3)
2×(1×24)
2×(1×24)
(3)
(3)
3×(1×24)
5×40
(4)
(4)
5×40
5×40
(4)
Specifications
Number of fuses
n
n
[V]
Fuse I
[A]
700
4
700
4
700
4
1000
4
1000
4
1000
4
700
6
1000
6
1000
6
700
2 × 6
1000
2 × 6
1000
2 × 6
2
Motor cable [mm
]
(2)
Cu: 3×95+50
Al: 3×120+70
Cu: 3×95+50
Al: 3×120+70
Cu: 3×95+50
Al: 3×120+70
Cu: 3×150+70
Al: 3×240Al+72Cu
Cu: 3×185+95
Al: 2×(3×95Al+29Cu)
Cu: 2×(3×95+50)
Al: 2×(3×150Al+41Cu)
Cu: 2×(3×120+70)
Al: 2×(3×185Al+57Cu)
Cu: 2×(3×150+70)
Al: 2×(3×185Al+57Cu)
AQ304441431479en-000101 / DPD00909