SECTION 6

TROUBLESHOOTING

STATUS CODES

This lift has several advanced safety systems
that monitor various sensors, switches and the
performance of the lift. To indicate the status of the
VPL there are 4-LEDs located on the Top Cap of the
tower. The table below explains the status indicated
by the 4-LEDs. LEDs are numbered from left to right,
while facing the tower from the platform side. Color
listed in brackets indicates LED is flashing.
See Figure 6-1.
NOTE: [COLOR] means flashing light.
STATUS LED
#1
#2
All OFF
Any Green or [Green]
Green
Green
[Green]
[Green]
[Green]
[Green]
Any Amber
Amber
Amber
Amber
STATUS
#3
#4
Green
Green
[Green]
[Green]
[Green]
Amber
Amber
Amber
HIGHLANDER II VERTICAL PLATFORM LIFTS:
HIGHLANDER II: SECTION 6
TROUBLESHOOTING
1
Figure 6-1
Lift will not function. Major Fault, No Power (and no
battery) or Low Power Mode. Service is Required.
Lift functional. No faults
All systems normal. Lift is OK to Operate.
Lift is in "Service Mode". Only Authorized Technicians
should Operate.
Lift is running on backup power. Lift is OK to Operate.
Lift is OK to Operate. Service is Required.
Lift is running on backup power and battery is Low. Lift
is OK to Operate for at least one full lift cycle.
Lift is on AC power and battery is Low. If lift transfers
to backup power it will only operate for at least one full
lift cycle. Service or replace batteries.