Harmar Mobility HIGHLANDER II Installation & Service Manual page 33

Vertical platform lift
Table of Contents

Advertisement

The control board has three (3) momentary switches and three (3) permanent cuttable switches/jumpers.
See Figure 6-5.
Brake Momentary
Switch
Service
Momentary Switch
BRAKE MOMENTARY SWITCH
The brake on the back of the gear motor is 24V
DC "fail safe," electromagnetic holding brake. The
brake is released when 24V DC is applied. Pressing
the BRAKE momentary switch will apply 24V DC and
release the brake with an audible "Click."
WARNING
!
Pressing and holding this switch could result in the
platform slowly drifting down.
3X Permanent
Cuttable Switches
Figure 6-5
This switch can be used to check brake operation
and is recommended to be used in the emergency
lowering procedure.
RESET MOMENTARY SWITCH
Pressing the RESET momentary switch will reset the
processor and exit "Service Mode" if board were
in that mode. "Out of Service Mode" flag is not
cleared by pressing the RESET switch.
HIGHLANDER II VERTICAL PLATFORM LIFTS:
HIGHLANDER II: SECTION 6
TROUBLESHOOTING
Reset Momentary
Switch
Install Manual
17FEB2021 | 630-00113 REV C
33