Install Cylinder; Install Outside Front; Perform Functional Check - Sargent 7800 Series Installation Instructions Manual

Mortise lock
Table of Contents

Advertisement

7800 and 8200 Series Mortise Lock
Used with Sectional Trim and V Series Indicators
Installation Instructions
5
Installation (cont.)
g

Install Cylinder

1. Thread cylinder into lock until flush with escutcheon
surface. (Figure 11)
• Pull key slightly out of cylinder to help thread
2. Tighten cylinder clamp screw with #2
Phillips screwdriver.
• Check operation and adjust if necessary.
Notes:
SARGENT logo must be horizontal
and on top. (Figure 12)
If double cylinder function is used, repeat
steps 1 and 2 for second cylinder.
Removable Core or Interchangeable Core cylinders
require a control key (key stamped with C) to remove and
install the core. This is not provided standard; it must be
requested separately. If requesting 1-bitted control key,
specify 113511 cut.
h

Install Outside Front

1. Tighten the two (2) lock screws completely: (Figure 13)
2. Attach outside front with two (2) flat head screws #8-32 x 1/4".
i

Perform Functional Check

DO NOT FORCE if resistance is encountered during functional
check. Refer back to Rehanding Indicator (if required) section
to ensure correct handing. Rehand if necessary.
1. Insert key into cylinder (if present) and rotate:
• Ensure there is no friction against lock
2. Check key retracts latch:
• Key should rotate freely.
3. Throw deadbolt (if present):
• Check key retracts both deadbolt
4. Test levers:
• Confirm latch and deadbolt (if installed) retract.
5. Verify indicator displays correct status when
locked and unlocked.
1-800-727-5477 • www.sargentlock.com
Copyright© 2019, 2020 SARGENT Manufacturing Company. All rights reserved. Reproduction in whole
or in part without the express written permission of SARGENT Manufacturing Company is prohibited.
into lock body.
case or any other obstructions.
and latch.
Cylinder
Clamp
Screw
Figure 11
Key and cylinder must be rotated as shown.
Correct
Figure 12
Lock screw
Outside front
#8-32 x 1/4"
Lock
screws
screw
6
Cylinder
Incorrect
Figure 13