Shut-Down Instructions; Cleaning Instructions - L.B. White Oval-U 100 Owner's Manual And Instructions

Radiant tube
Table of Contents

Advertisement

Available languages

Available languages

FIG. 11
On
5. This pre-purge is a safety feature and a normal
operational characteristic prior to ignition taking
place. After five (5) seconds, the igniter will spark.
6. The ignition control will make up to three trials for
ignition. Each trial for ignition will take approximate-
ly ten seconds. If the main burner does not light, the
system will lock out, and a three flash pattern will
be given by the red LED.
NOTE: It is normal for air to be trapped in the gas hose
on new installations. The heater may try more
than once for ignition before the air is finally
purged from the line and igntion takes place.

Shut-Down Instructions

If the heater is to be shut down for cleaning, main-
tenance or repair, follow steps 1 - 4. Otherwise, set
the thermostat to off or no heat for standard shut
down.
1. Close all manual fuel supply valves.
2. With the heater lit, allow heater to burn off
excess fuel in gas supply hose.
3. Turn thermostat to off or no heat position.
4. Disconnect the heater from the electrical supply
Owner's Manual • Oval-U 100
Oval-U 100
Fault
Red
Green
Radiant Tube Heaters

Cleaning Instructions

WARNING
Fire, Burn and Explosion Hazard
■ This heater contains electrical and mechanical
components in the gas management, safety and
airflow systems.
■ Such components may become inoperative or
fail due to dust, dirt, wear, aging, or the corrosive
atmosphere of an animal confinement building.
■ Periodic cleaning and inspection as well as
proper maintenance are essential to avoid seri-
ous injury or property damage.
1. Before cleaning, close the fuel supply valve to the
heater and disconnect the electrical supply. Allow
heater to cool.
2. The heater should have dirt or dust removed periodi-
cally:
a. After each flock or between building re-popula-
tion, give the heater a general cleaning using
pressurized air or a soft brush on its burner box,
reflectors, and tubes.
b. At least once a year, give the heater a thorough
cleaning. At this time, open the burner box and
brush or blow off control components, and fan
motor assembly. Ensure the burner air inlet
venturi ports and the throat of the casting are free
of dust accumulation.
c. When washing with water, do not spray water into
the burner box or the tubes. Observe and obey
the Warning within these Cleaning Instructions.
This same Warning is supplied on the heater.
Radiant Tube Heaters