Sediment Trap Assembly - L.B. White Oval-U 100 Owner's Manual And Instructions

Radiant tube
Table of Contents

Advertisement

Available languages

Available languages

FIG. 6
Eyebolt
Temperature Sensor Location
FIG. 7
WATER LINES
FEED LINE
LITTER
Air Turbulation Strips
& Exhaust Cap
The exhaust cap and the two air
turbulation strips are factory installed.
See Service Parts Schematic for
replacement.

Sediment Trap Assembly

Assemble the tee, nipple, and cap to the nipple at the
gas inlet of the heater. See Fig. 8. Use a wrench to
hold the pipe nipple when installing the sediment trap.
Tighten securely. The sediment trap assembly must
always be mounted in a vertical position. Check all
connections for gas leaks using approved gas leak
detectors.
Owner's Manual • Oval-U 100
Oval-U 100
5 ft. on center
4 ft. on center
Hanging Chains
HEATER
INSIDE WATER LINES
DESPERDICIOS
5 FT.
Radiant Tube Heaters
Exhaust Vent
S-Hooks
SENSOR LOCATED DIRECTLY
SENSOR IN PROXIMITY
ABOVE INSIDE WATER LINE AND
TO AN INSIDE WATER LINE
12-18 IN. ABOVE LITTER
WATER LINE
DE 12"
FEED LINE
A 18"
SENSOR
12-18 IN.
ABOVE LITTER
FIG. 8
NIPPLE
TO GAS CONTROL VALVE INLET
Radiant Tube Heaters
13
2X4 Support
Ceiling Joists
Clamp
TEE
NIPPLE
CAP