L.B. White Oval-U 100 Owner's Manual And Instructions

L.B. White Oval-U 100 Owner's Manual And Instructions

Radiant tube
Table of Contents

Advertisement

Available languages

Available languages

Quick Links

View this manual online at www.lbwhite.com
Attention
The Oval-U 100 heater has been
designed, tested, and evaluated
by the L. B. White Company as a
radiant tube heater according to
the requirements of standard IAS
U.S. Requirements 8-94. The tube
heater is designed specifically for
the intended use of heating poultry
confinement buildings.
WITH YOUR LOCAL FIRE
SAFETY AUTHORITY, YOUR
LOCAL FUEL GAS SUPPLIER,
OR THE L.B. WHITE COMPA-
NY IF YOU HAVE QUESTIONS
REGARDING APPLICATIONS.
www.lbwhite.com
SEE ASSEMBLY
INSTRUCTIONS
INSIDE
Please refer to important
elevation information on
inside cover.
WORLD PROVIDER - INNOVATIVE HEATING SOLUTIONS
411 Mason Street, Onalaska, WI 54650 • 800-345-7200 • 608-783-5691 • 608-783-6115 (fax) • www.lbwhite.com
Oval-U 100
CHECK
Congratulations!
You have purchased the finest radiant tube heater available for
the heating of poultry confinement buildings.
Your new L.B. White radiant heater incorporates the benefits
from the most experienced manufacturer of heating products
using state-of-the-art technology.
We, at L.B. White, thank you for your confidence in our products
and welcome any suggestions or comments you may have...call
us toll free at (800) 345-7200.
Owner's Manual and Instructions
Radiant Tube
100,000 Btuh
UT100
Propane Vapor Withdrawal
or Natural Gas
SCAN THIS
with your smartphone or
visit http://goo.gl/yyKxJo to
view maintenance videos
for L.B.White heaters.
* Requires an app like QR Droid
for Android or for iPhone

Advertisement

Chapters

Table of Contents
loading

Summary of Contents for L.B. White Oval-U 100

  • Page 1 We, at L.B. White, thank you for your confidence in our products and welcome any suggestions or comments you may have...call us toll free at (800) 345-7200. SEE ASSEMBLY...
  • Page 2: Table Of Contents

    If you require a high elevation product, did not specify when ordering, and/or the box this unit came in does not have an alternate altitude designation sticker please contact technical support. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 3 ■ SAVE THIS OWNER’S MANUAL FOR FUTURE USE AND REFERENCE. ■ OWNER’S MANUALS AND REPLACEMENT LABELS ARE AVAILABLE AT NO CHARGE. SEE WEBSITE, OR FOR ASSISTANCE, CONTACT L.B. WHITE AT 1-800-345-7200. WARNING ■ PROPER GAS SUPPLY PRESSURE MUST BE PROVIDED TO THE INLET OF THE HEATER.
  • Page 4 Minimum safe distances of heater from nearest combustible materials Sides (ft.) See Fig. 1 on page 5. Discharge End Below radiant tubes Temperature See Fig. 7 on page 13 of the owner’s manual. sensor location Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 5: General Information

    This manual will instruct you in the operation and care of your radiant heater. Have your qualified The L.B. White Co., LLC has a policy of continuous installer review this manual with you so that you fully product improvement. It reserves the right to change understand the heater and how it functions.
  • Page 6: Safety Precautions

    ■ Always be sensitive to the slightest gas odor. If you continue to detect any gas odor, no matter how small, treat it as a serious leak. Immediately go into action as discussed previously. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 7 Radiant Tube Heaters Attention - Critical Points to Remember! 2. All installations and applications of L.B. White heat- ■ Propane gas and natural gas have a distinctive odor. Learn to recognize these odors. (Reference ers must meet all relevant local, state and national “Fuel Gas Odor”...
  • Page 8: Inlet Air Requirements

    Houses with attic soffit vent area smaller than ridge cap vent area b. Heater air inlet located within 20 ft. of building ventilation fans c. Locations where wind and/or the elements can cre- ate a negative pressure. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 9 For inlet runs up to 20 ft., use smooth 4 in. iD PVC. For runs over 20 ft., use 6 in. ID PVC Do not locate the heater’s air inlet by any building air inlet. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 10: General Installation Instructions

    Radiant Tube Heaters General Installation Instructions 8. Always use pipe joint compound that is resistant 1. Read all safety precautions and follow L.B. White to liquefied petroleum gas and natural gas. recommendations when installing this heater. If during the installation of the heater, you suspect that a part is 9.
  • Page 11 12. Install the proper size of gas supply line to assure proper functioning of the heaters. Consult your fuel gas supplier, or the L.B. White Co., LLC for proper line sizing and installation. 13. Light according to instructions on heater or within Owner’s Manual.
  • Page 12: Hanging The Tubes

    9. Using a leveler, ensure the tube/shroud assembly is level. See Fig. 6. 6. Attached the chains to the burner box eyebolts and to the shrouds S-hooks. FIG. 4 Hanging Chains S-Hooks Eyebolts Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 13: Sediment Trap Assembly

    Tighten securely. The sediment trap assembly must always be mounted in a vertical position. Check all connections for gas leaks using approved gas leak detectors. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 14: Manual Shut Off Valve, Hose & Regulator Assembly

    4. On a call for heat, the ON green light will be lit and the motor will start up and run for five (5) seconds. A series tap thermostat may be used to operate the See Fig. 11. tube heater. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 15: Shut-Down Instructions

    2. With the heater lit, allow heater to burn off excess fuel in gas supply hose. 3. Turn thermostat to off or no heat position. 4. Disconnect the heater from the electrical supply Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 16: Maintenance Instructions

    ■ Failure to follow this warning will result in burns are suspect. causing injury. 4. Check all gasketing on burner box and fan housing discharge. Ensure all is in good condition. Replace any gasket material if suspect Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 17 The tip of the igniter is exposed to a harsh environ- ment consisting of high temperatures and combus- FIG. 13 tion products. Periodic servicing is required. (1/8 IN.) Ground rod Electrode Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 18 See Fig. 17 for location. Its purpose is to prove to the ignition control that there is a sufficient difference in pressure within the burner box before the ignition control sends power to open the gas control valve. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 19 • Blue orifice into white stem on switch. To test the switch: • Disconnect the pressure switch wiring at terminals PSI and PSO of the ignition control. • Route the wires so both are exterior of the burner Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 20 Also refer to “Operation Sequence” within this manual FIG. 20 as needed to understand operation of the ignition control during a call for heat. FIG. 21 Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 21 35 in. W.C. (may also be Securely tighten the pressure barb. ordered from L.B. White, part number 00764) 6. Open the fuel supply valves to the heater, recon- Bushing, 1/2 in.x 1/8 in.
  • Page 22 4. Reconnect hose and adapter to sediment trap. tighten securely. 5. Open fuel supply valve and reconnect electrical supply to heater. Start the heater and check for gas leaks. Set thermostat to desired temperature. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 23: Troubleshooting Information

    To effectively use the flow charts, you must first -- Process starts again on a call for heat. identify what the problem is by the light pattern of the red diagnostic light. Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 24 Oval-U 100 Radiant Tube Heaters Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 25 Oval-U 100 Radiant Tube Heaters Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 26 Oval-U 100 Radiant Tube Heaters Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 27: Electrical Connection And Ladder Diagram

    HAVING A TEMPERATURE RATING OF AT LEAST 302° F (150°C)./SI SE DEBE CAMBIAR CUALQUIER CABLE ORIGINAL PROPORCIONADO CON EL APARATO, SE DEBE CAMBIAR POR UN CABLE CON UNA CLASIFICATION DE TERMPERATURA DE AL MENOS 302 F(150 C) Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 28: Service Parts Identification

    Oval-U 100 Radiant Tube Heaters Service Parts Identification Schematic - Tube/Reflector Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 29 Vent cap, AR 573971 Air turbulation strip 572892 Clamp, 4 in. round 573009 “S” hook and chains 574234 U-tube support end plate 574229 Tube, 4 in. bent “U” 574230 End cap reflector 574231 Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 30 Oval-U 100 Radiant Tube Heaters Service Parts Identification Schematic - Burner Box Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 31 Regulator, second stage, propane gas 550-06553 Regulator, second stage, natural gas 500-24414 Regulator, second stage, LPG/NG 500-21999 31** Complete gasket kit for burner box 572896 * Accessory sold separately ** Not illustrated Owner’s Manual • Oval-U 100 Radiant Tube Heaters...
  • Page 32: Warranty Policy

    L.B. White will not be liable for any incidental operated, and maintained in accordance with the or consequential damages directly or indirectly related...
  • Page 33 En L.B. White, le agradecemos la confianza depositada en nuestros productos y serán bien recibidos los comentarios y las sugerencias que pueda tener. Llámenos gratuitamente al (800) 345-7200.
  • Page 34 Calefactore de tubo radiante Oval U-100 ÍNDICE Especificaciones del calefactor ..................4 Información general ......................5 Distancias de seguridad con materiales combustibles ...........5 Precauciones de seguridad ....................6 Requisitos de entrada de aire ..................9 Instrucciones generales de instalación .................10 Configuración inicial .....................12 Colgado de los tubos ....................12 Tiras y ventilación de turbulencia de aire ..............15 Conjunto del colector de sedimentos ................15 Conjunto de válvula de cierre manual, manguera y regulador ........15...
  • Page 35 ■ GUARDE ESTE MANUAL DEL USUARIO PARA CONSULTARLO Y USARLO EN EL FUTURO. ■ LOS MANUALES DEL USUARIO Y LAS ETIQUETAS DE REPUESTO ESTÁN DISPONIBLES SIN COSTO. CONSULTE EL SITIO WEB O CONTÁCTESE CON L.B. WHITE AL 1-800-345-7200. ADVERTENCIA ■ SE DEBERÁ PROPORCIONAR UNA PRESIÓN DE SUMINISTRO DE GAS APROPIADA A LA ENTRADA DEL CALEFACTOR.
  • Page 36 Calefactore de tubo radiante Oval U-100 Especificaciones UT100 Entrada máxima por hora en BTU/H 100,000 Consumo de combustible por hora LPG (lbs.) (máx.) NG (cu. ft.) Presión de suministro de gas MÁX. aceptable para el propósito de ajuste 13,5 de entrada (en pulgadas de columna de agua) 11,0 MÍN.
  • Page 37: Información General

    Póngase en contacto con su distribuidor L. B. White o serie. con L.B. White Company, LLC para obtener ayuda, o si tiene preguntas sobre el uso del calefactor o sobre su Este manual le brindará instrucciones sobre el funciona- aplicación.
  • Page 38: Precauciones De Seguridad

    Calefactore de tubo radiante Oval U-100 Precauciones de seguridad ADVERTENCIA Peligro de asfixia ■ No use este calefactor radiante para calefaccionar lugares donde vivan seres humanos. ■ No lo use en áreas sin ventilación. ■ El flujo de aire de ventilación y combustión no debe obstruirse. ■...
  • Page 39 2. Todas las instalaciones o aplicaciones de los el calefactor a funcionar. El conjunto de la manguera calefactores de L.B. White deben cumplir con todos debe protegerse de los animales y del contacto con los códigos locales, estatales y nacionales, incluidos superficies calientes durante el uso.
  • Page 40: Requisitos De Entrada De Aire

    Calefactore de tubo radiante Oval U-100 Este calefactor requiere aire limpio y fresco de un entor- 10. Controle que no haya fugas de gas y que el no de presión atmosférica normal para un funcionamiento funcionamiento sea adecuado tras la instalación del y una combustión adecuados.
  • Page 41 Calefactore de tubo radiante Oval U-100 ASPIRACIÓN DEL AIRE DE ENTRADA DESDE EL ÁTICO FIG. 2 Tapa de Brida para el techo ventilación Asegúrese de que la tapa de entrada Tubo de no quede obstruida por el aislante. entrada de aire 12 in desde el...
  • Page 42: Instrucciones Generales De Instalación

    Instrucciones generales de instalación 1. Lea todas las precauciones de seguridad y siga las reco- de fugas de gas se realiza de la siguiente manera: mendaciones de L.B. White cuando instale este calefactor. Si durante la instalación del calefactor sospecha que una ADVERTENCIA pieza está...
  • Page 43 12. Instale una línea de suministro de gas del tamaño y del tipo adecuados para garantizar el funcionamien- to correcto de los calefactores. Comuníquese con su proveedor de gas o con L.B. White Co., Inc. para determinar el tamaño adecuado de la línea y su correcta instalación.
  • Page 44 open eye hooks. OPEN EYE BOLT Calefactore de tubo radiante Oval U-100 11 IN. 1 FT Colgar el conjunto de tubos / cubierta y la caja del BURNER DISCHARGE quemador FIG. 6 Los tubos / cubiertas y la caja del quemador vienen de FIG.
  • Page 45: Conjunto Del Colector De Sedimentos

    Calefactore de tubo radiante Oval U-100 FIG. 6 5 pies (1,5 m) en el centro Vigas de techo de soporte 2x4 4 pies (1,2 m) en el centro Cadenas colgantes Cáncamo Ventilación de escape Abrazadera Ganchos en S Ubicación del sensor de temperatura FIG.
  • Page 46: Controles Del Calefactor

    Calefactore de tubo radiante Oval U-100 Válvula de cierre Instalación del conjunto manual, manguera de conexión en serie del y regulador termostato 1. Ensamble los componentes entre sí. Vea la Fig. 9. Esta vista muestra el armado general de los componentes. -- Conecte el cable de alimentación en la ficha hembra del El regulador siempre se debe montar de modo que su conjunto de cables del termostato.
  • Page 47: Instrucciones De Apagado

    Calefactore de tubo radiante Oval U-100 Instrucciones de limpieza FIG. 11 ADVERTENCIA Peligro de incendio, quemaduras y explosión ■ Este calefactor contiene componentes eléctricos y mecá- nicos en los sistemas de gestión del gas, seguridad y flujo de aire. ■ Estos componentes pueden dejar de funcionar o fallar debido a polvo, suciedad, desgaste, envejecimiento o la atmósfera corrosiva de un edificio en el que se confinan animales.
  • Page 48: Instrucciones De Mantenimiento

    Calefactore de tubo radiante Oval U-100 Instrucciones de 3. Los reguladores se pueden desgastar y pueden no funcionar adecuadamente. Pida a su proveedor de mantenimiento gas que verifique los códigos de fecha que figuran en todos los reguladores instalados y las presiones que llegan al aparato para asegurarse de que el Antes de cada uso: regulador sea adecuado para un uso continuo.
  • Page 49 Calefactore de tubo radiante Oval U-100 Encendedor Conjunto del motor y ventilador La punta del encendedor está expuesta a un entorno hostil (correspondiente a las altas temperaturas y a los productos de la combustión). Se requiere un mantenimiento periódico 1. Desconecte los cables del motor. de esta.
  • Page 50 Calefactore de tubo radiante Oval U-100 Interruptor de presión di- FIG. 17 Interruptor de ferencial de aire, tubería y presión de aire orificios de presión Orificio: Consulte la Fig. 16. Asegúrese de que este orificio esté limpio. Si el orificio está tapado, retire los retener el clip y (+) POSITIVO limpiar el orificio con aire comprimido.
  • Page 51 Calefactore de tubo radiante Oval U-100 Para probar el interruptor: FIG. 19 • Desconecte el cableado del interruptor de presión en los terminales PSI y PSO del control de encen- dido. • Dirija los cables de modo que estén en el exterior de la caja de quemadores cuando la puerta de la caja esté...
  • Page 52 Obtenga dos manómetros con capacidad calentador y encienda el calentador. para leer hasta 35 pulg. de columna de agua (también se puede pedir a L.B. White, número de pieza 00764) Buje, 1/2 in x 1/8 in Accesorio con lengüeta de 1/8 in Manual del propietario •...
  • Page 53: Información De Resolución De Problemas

    Calefactore de tubo radiante Oval U-100 3. Quite los manómetros y la tornillería asociada. Instale B. Lectura de presiones. tapones en la válvula de control de gas y en el conector. 1. Con el calefactory funcionando, los manómetros deberían decir Ajuste bien todos los elementos.
  • Page 54 Calefactore de tubo radiante Oval U-100 operación del módulo de encendido y los componentes relaciona- -- La válvula de control de gas se abre. dos es fundamental, dado que se asocian directamente con los -- Se produce el encendido. procedimientos de resolución de problemas suministrados en los -- El encendedor continúa destellando durante 4 segun- diagramas de flujo.
  • Page 55 Calefactore de tubo radiante Oval U-100 Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 56 Calefactore de tubo radiante Oval U-100 Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 57 Calefactore de tubo radiante Oval U-100 Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 58 Calefactore de tubo radiante Oval U-100 Conexión eléctrica y diagrama de escalera Black/Negro Blue/Azul GV GV BK or/o W Brown/Marrón FAULT L.E.D.(RED) BR or/o R* LED DE CULPA (ROJO) Green/Verde GR or/o R* Orange/Naranja Red/Rojo White/Blanco Gas Control Valve/Válvula De L.E.D.
  • Page 59 Calefactore de tubo radiante Oval U-100 Notas Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 60 Calefactore de tubo radiante Oval U-100 Diagrama de identificación de piezas de mantenimiento - Tubo / Reflector Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 61 Calefactore de tubo radiante Oval U-100 Lista de piezas - Tubo / Reflector Item Description Part# Reflector, Oval-U 574226 Placa de extremo del calentador 574227 Tubo, calorizado, 4 pulgadas x 10 pies con abrazadera 573011 Tubo, ovalado, 4 pulgadas x 10 pies con abrazadera 574228 Tapa de ventilación, AR 573971...
  • Page 62 Calefactore de tubo radiante Oval U-100 Diagrama de identificación de piezas de mantenimiento - Burner Box Manual del propietario • Calefactore de tubo radiante Oval U-100...
  • Page 63 Calefactore de tubo radiante Oval U-100 Lista de piezas - Burner Box Pestillos y pasador Item Description Part # Pestillos y pasador 573775 LED rojo 573769 LED verde 573770 15** Mazo de cables 573681 Encendedor con soporte 574220 Cable de encendido 572847 Interruptor de presión diferencial de aire 573682...
  • Page 64: Política De Garantía

    L.B. White me a las Instrucciones de instalación y mantenimiento, con respecto al equipo, incluidas reclamaciones basadas en las guías de seguridad y las etiquetas de cada unidad.

This manual is also suitable for:

Ut100