Saving The Serial File To A Pc; Copying A Serial Table For Uploading To Different Tvm-Rx03S - AMX Endeleo TVM-1600 Operation/Reference Manual

Endeleo managed tv distribution hub
Hide thumbs Also See for Endeleo TVM-1600:
Table of Contents

Advertisement

Serial Device Control

Saving The Serial File To a PC

The serial protocol is stored on the receive unit and rather than repeat the above process, it is possible to
copy (get) a serial control table from one receive unit to others across the network.
1. To capture the serial control table, use the following command (FIG. 53);
Saving the serial file
FIG. 53
2. After hitting enter, the Transfer Successful message (FIG. 54) is returned.
FIG. 54
Successful transfer of serial file

Copying a Serial Table For Uploading To Different TVM-RX03s

It may be necessary to copy the file sXXX.001 to other files named sXXX.002 through sXXX.016 in
order to upload the serial files to TVM-RX03 units on all ports of the TVM-1600.
For example, if you used tftp to get a serial file from a TVM-RX03 unit on port 1, your file will have a
.001 file extension. To send this file to a TVM-RX03 on port 16 it would need a file extension of .016.
1. Use the Copy command (FIG. 55) to copy the serial files to different extensions on the PC;
FIG. 55
Copying a serial file
2. Upon completion, a successful copy message is displayed (FIG. 56). The copied file can be
uploaded (put) onto other RXs.
FIG. 56
Successful copy of serial file
3. To upload (put) this Serial file to a TVM-RX03 unit on port 16 of the TVM-1600 use the tftp
command with the new file sSonyLCD.016. The command is shown below;
4. Push Enter to execute the command.
46
tftp –i [Hub IP Address] get sname.001
Where sname is a user-defined name for the serial file, as long as it starts with an "s" e.g.
sSonyLCD.001.
The file extension is the port number the TVM-RX03 is connected to. Port 1 is .001 through
port 16, which is .016.
copy sXXX.001 sXXX.016 <enter>
XXX is the file name of the Serial table (e.g. sSonyLCD.001)
.001 represents the port number of the TVM-1600.
tftp –i 192.168.1.200 put sSonyLCD.016
TVM-1600 Endeleo Managed TV Distribution Hub