6. INSTALLATION AND CONNECTION

6.1 LOCK AND LATCH
MOUNTING
1. Mount the lock on a wall, at a distance of
10mm from the locker wall edge.
2. Connect the lock to the power supply
3. Insert the latch into the lock.
4. Test operability of the lock – as voltage
is applied, the lock must push out the
latch.
5. Fix the latch on the door.
6. Test operability in door closing.
6.2 CONNECTING PROCEDURE
The lock operation is controlled by supplying and blocking power. For this purpose a controller
(control board) or a switch (button) is generally used. The controller is mounted in accordance
with its certificate.
See operating voltage range in cl. 5.2. Avoid supply of increased voltage.
Ensure a reliable electric contact. To prevent short-circuit, insulate places of
connection.
Purpose of terminals:
1–2 – lock power supply;
3 – normally open contact of the lock state sensor;
4 – common contact of the sensor;
5 – normally open contact of the door sensor;
Polarity of power supply wire connection does not matter.