PROMIX SM101 Operating Manual

Electromechanical lock

Advertisement

Quick Links

05.04.2019
engineering and production center
OPERATING MANUAL
Technical description. Installation manual. Certificate.
ПШБА.304268.101 РЭ
PATENT FOR INVENTION
No.2382861
1. PURPOSE
Electromechanical locks series Promix-SM101 with a ball locking mechanism (hereinafter
referred to as the locks) are intended for locking of swing doors that open both inward and
outward, which can be opened remotely by energizing/de-energizing (depending on the version)
the lock with DC supply voltage by means of switches (buttons) or controllers of access
monitoring and control systems, audio and video intercoms, code panels or other devices. The
lock design and mounting method allow them to be installed inside or outside the protected
premises on practically any door types.
2. LABELING
The label stuck to the lock body contains the following information:
1.
Lock model.
2.
Patent number.
3.
Nominal supply voltage.
4.
Nominal consumed current.
5.
Date of manufacture and QCD mark
6.
Identification number.
Manufacturer's website.
7.
For the list of lock modifications that can be ordered, see 5.2.
The color of the product is shown on the sticker stuck to the box, after the product name. Series
colors: Silver, White, Brown.
Other colors are provided optionally.
Availability of built-in sensors:
0(Absence) - no sensors. 3 - door and lock sensors
Supply voltage:
0 - 12V. 1 -24V
Version:
0 - normally opened, 1 - normally closed
ELECTROMECHANICAL LOCK
Promix-SM101
1
ELECTROMECHANICAL LOCK
2
Patent No. 2382861
3,4
12 V=0.1 A
Made in Russia
No. 100 001008
6,7
An example of information
layout on the label.
5
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SM101 and is the answer not in the manual?

Questions and answers

Summary of Contents for PROMIX SM101

  • Page 1 No.2382861 1. PURPOSE Electromechanical locks series Promix-SM101 with a ball locking mechanism (hereinafter referred to as the locks) are intended for locking of swing doors that open both inward and outward, which can be opened remotely by energizing/de-energizing (depending on the version) the lock with DC supply voltage by means of switches (buttons) or controllers of access monitoring and control systems, audio and video intercoms, code panels or other devices.
  • Page 2: Design And Principle Of Operation

    Promix-SM101 3. SET OF DELIVERY 1 – Lock 1 pc. 2 – Bracket 1 pc. 3а – Lock fixture tie M4 2 pcs. 12а 3b – Screw М4х16 (pan head) 2 pcs. 4а – Self-tapping screw 4х30 (cup 2 pcs.
  • Page 3: Technical Data

    Promix-SM101 5. TECHNICAL DATA OPERATING CONDITIONS The lock operation environment must be explosion-safe, free of current-conducting dust or gases that cause metal corrosion and destroying insulation of current conductors and electric elements, free of current-carrying dust or water vapor, and preventing ingress of water, steam, fuel and lubricants.
  • Page 4: Installation And Connection

    Promix-SM101 Lock and latch overall and mounting dimensions. Sensors module Promix-SM101.00.3; Promix-SM101.01.3 Promix-SM101.00; Promix-SM101.01 Emergency exit rod Promix-SM101.10; Promix-SM101.11 6. INSTALLATION AND CONNECTION 6.1 LOCK MOUNTING Lock mounting depends on door frame ledge width А. If the ledge width is less than 25.5mm, use angular brackets 10.
  • Page 5 Promix-SM101 Door frame ledge width А (see Fig.) 0…17 mm Door frame Place for wire Fastening to door Fastening to frame lock bracket Drill five holes 4.2…4.7 mm in diameter at the shown places of the angular bracket. The wide side of the angular bracket adjoins the lock, and the narrow side - to the door frame.
  • Page 6 Promix-SM101 Door frame ledge width А (see Fig.) 17…25.5 Door frame 12а Place for Fastening wire to door Fastening to frame lock bracket Drill five holes 4.2…4.7 mm in diameter at the shown places of the angular bracket. The narrow side of the angular bracket adjoins the lock, and the wide side - to the door frame.
  • Page 7 Promix-SM101 Door frame ledge width А exceeds 25.5 DOOR FRAME 4а DOOR 1. Close the door firmly. 2. Apply the template 11 to the upper corner of the door frame, on the door handle side. Press the marked edge of the template snugly to the door leaf.
  • Page 8 See operating voltage range in 5.2. Avoid supply of overvoltage. Connect sensor leads: White, Green – output of the lock state sensor Brown, Yellow – output of the door position sensor. An example of the lock connection to the remote control system Promix-RDS. 220 V Lock Controller Promix-CR.RX Remote control Promix-CR.TX...
  • Page 9 Promix-SM101 Provide a reliable electriccontact. To prevent short-circuit, insulate places of connection. 7. SPECIAL ASPECTS OF INSTALLATION AND OPERATION 1) The possibility of using of the locks for restriction of access to the premises and the place of installation (outdoors or indoors) are determined by the installation organization on the...
  • Page 10: Troubleshooting

    Promix-SM101 TROUBLE-SHOOTING Troubles and problems Remedies Using a tester, check integrity of the lock power circuit. Press the door against the door frame and pull the emergency exit rod, or apply an elevated voltage NC lock does not open when supply voltage of 20-30V to the lock for a short time.
  • Page 11: Maintenance

    18 months from the day of acceptance by the manufacturer’s QCD. Within the period of warranty, ETC PROMIX LLC undertakes to repair defective products free of charge. Expenses for transporting the product to the place of repair and back will be borne by the Buyer.
  • Page 12: Acceptance And Packing Certificate

    QCD mark on the body, was manufactured and accepted in compliance with Specifications ПШБА.304268.001 ТУ, obligatory requirements of state standards and current technical documentation, recognized as fit for operation and packed by ETC PROMIX LLC. PROMIX Engineering and Technical Center LLC Russia, 214030, Smolensk, Krasninskoye sh., 35, lit.

Table of Contents