Levelflex M FMP41C PROFIBUS PA
Date
Software version
04.2002
01.02.00
08.2003
01.02.02
07.2004
01.02.04
01.2005
01.02.06
03.2006
01.04.00
Endress+Hauser
9.5

Return

The following procedures must be carried out before a transmitter is sent to Endress+Hauser e.g.
for repair or calibration:
• Remove all residue which may be present. Pay special attention to the gasket grooves and crevices
where fluid may be present. This is especially important if the fluid is dangerous to health, e.g.
corrosive, poisonous, carcinogenic, radioactive, etc.
• Always enclose a duly completed "Declaration of contamination" form (a copy of the "Declaration
of contamination" is included at the end of this operating manual). Only then can
Endress +Hauser transport, examine and repair a returned device.
• Enclose special handling instructions if necessary, for example a safety data sheet as per
EN 91/155/EEC.
Additionally specify:
• An exact description of the application
• The chemical and physical characteristics of the product
• A short description of the error that occurred (specify error code if possible)
• If necessary, give the error code
9.6

Disposal

In case of disposal please seperate the different components according to their material consistence.
9.7

Software history

Software modifications
Original software.
Operated via:
– ToF Tool
– Commuwin II (as of Version 2.08-1 Update C)
– HART-Communicator DXR375 withRev. 1, DD 1.
• Function group: envelope curve display
• Katakana (japanese)
• current turn down (HART only)
• the customer tank map can be edited
Operated via:
– ToF Tool
– Commuwin II (ab Version 2.08-1 Update C)
– HART-Communicator DXR 375 mit Rev. 1, DD 1.
• "mapping" function improved
• Specification of the measuring accuracy at the ende
of the probe
Function "echo lost" improved
• Function "detection window"
• Description of Instrument Functions
• Operating menu extended
Documentation
Description of
Instrument Functions
BA277F/00/en/11.03
52021035
BA245F/00/en/02.04
52011936
BA277F/00/en/02.04
52021035
BA277F/00/en/06.04
BA245F/00/en/06.04
52021035
52011936
BA277F/00/en/01.06
BA245F/00/en/01.06
52021035
52011936
----
BA277F/00/en/05.06
52021035
BA245F/00/en/06.06
52011936
BA277F/00/en/11.06
52021035
BA277F/00/en/03.09
71074803
BA00277F/00/EN/13.10
71120288
Trouble-shooting
----
----
81