Endress+Hauser Levelflex M FMP41C Operating Instructions Manual page 2

Guided level-radar
Hide thumbs Also See for Levelflex M FMP41C:
Table of Contents

Advertisement

!
2
Brief Operating Instructions
Levelflex M - Brief operating instructions
KA189F/00/a2/03.07
52012501
000
Contrast:
measured value
-
+
E
Group
+
-
selection
00
002
003
basic setup
tank
medium
properties
property
+
01
- standard
- unknown
safety settings
- aluminium tank
- 1.4 ... 1.6
- 1.6 ... 1.9
- plastic tank
- bypass/pipe
- 1.9 ... 2.5
- coax-probe
- 2.5 ... 4
- concrete
- 4 ... 7
wall
- > 7
03
030
031
length
end of
probe
adjustment
probe
length
- free
04
- tie down
linearisation
isolated
05
- tie down
gnd.
extended calibr.
092
09
... ...
display
language
0E
09A
envelope curve
plot settings
- envel. curve
- substracted signal
- mapping
-
0A
0A0
0A1
diagnostics
present
previous
error
error
0C
system
parameters
Note!
This Operating Instructions explains how to install and commission the level transmitter.
All functions that are required for a typical measuring task are taken into account here.
In addition, the Levelflex M provides many other functions for optimizing the measuring point and
conventing measured values. These functions are not included in these Operating Instructions.
An overview of all device functions can be found on → ä 90.
The Operating Instructions BA00245F/00/EN "Description of Instrument Functions" provides an
extensive description of all device functions which can be found on the enclosed CD-ROM.
The Operating Instructions can also be found on our homepage: www.endress.com
+
or
+
004
005
006
process
empty
full
cond.
calibr.
calibr.
- standard
input E
input F
- fast
(see sketch)
(see sketch) displayed
change
- slow
change
- test: no filter
032
033
034
probe
probe
determine
length
length
If shortened
please enter probe length here.
09B
recording
curve
- single curve
- cyclic
0A3
0A4
reset
unlock
parameter
(333 = reset customer parameters)
= 100: unlocked
¹ 100: locked
Levelflex M FMP41C PROFIBUS PA
E
E
E
008
051
052
dist./
check
range of
meas value
distance
mapping
D and L are
confirm
suggestion
or specify
range
FMP43
reference point of
measurement
UB
D
threaded
LN
connection
¾ or
1 ½
BSP
L
(G
¾ or G ½)
1
¾ or 1½ NPT
:
reference point of
measurement
UB = upper blocking distance
E = empty distance (= zero)
... ...
D = distance
Endress+Hauser
008
dist./
meas value
053
start
mapping
FMP40
FMP41C
FMP45
100%
E
F
0%
F = measuring span
LN = probe length
L = level
52012501
L00-FMP40xxx-19-00-00-en-012