D PTING THE PPLI NCE
TO FUNCTION WITH DIF-
FERENT TYPES OF G S
If a different gas from that one indicated
on the label is used, you need to adapt the
cooktop to this new situation.
If the injectors are not supplied they
can be obtained from the "Service
Centre".
Select the injectors to be replaced
according to the table on next page).
The nozzle diameters, expressed in
hundredths of a millimetre, are marked
on the body of each injector.
Fig. 6.3
J
OPER TIONS TO BE PER-
FORMED WHEN SUBSTITUT-
ING THE INJECTORS
Remove the pan-supports, the burner
covers and the knobs;
Using a wrench substitute the injec-
tors "J" (Fig. 6.3 - 6.4) with those
ones suitable for the type of gas for
which it is to be used.
The burners are conceived in such a
way so as not to require the adjust-
ment of the primary air.