Par .
Function
P9-01 Enable Input source
P9-02 Fast stop Input source
P9-03 Run forward Input source
P9-04 Run reverse Input source
P9-05 Latch function enable
P9-06 Reverse Input source
P9-07 Reset Input source
P9-08 External trip Input source
P9-09 Terminal control select source
P9-10 Speed reference 1
P9-11 Speed reference 2
P9-12 Speed reference 3
P9-13 Speed reference 4
P9-14 Speed reference 5
P9-15 Speed reference 6
P9-16 Speed reference 7
P9-17 Speed reference 8
P9-18 Speed ref.select bit 0 source
P9-19 Speed ref.select bit 1 source
P9-20 Speed ref.select bit 2 source
P9-21 Preset speed select bit 0 source
P9-22 Preset speed select bit 1 source
P9-23 Preset speed select bit 2 source
P9-24 Accel. ramp select bit 0 source
P9-25 Accel. ramp select bit 1 source
P9-26 Decel. ramp select bit 0 source
P9-27 Decel. ramp select bit 1 source
P9-28 Motorised pot up input source
P9-29 Motorised pot up down source
P9-30 Speed limit forward input source
P9-31 Speed limit reverse input source
P9-33
Analog output AO1 source
P9-34
Analog output AO2 source
P9-35
Relay 1 control source
P9-36
Relay 2 control source
P9-37
Display scaling control source
P9-38
PID reference source
P9-39
PID feedback source
P9-40
Torque reference source
P9-41
Relay 3,4 & 5 function
GFK-3111A
Setting Range
These parameters allow the user to directly select the source of the various
command points. Parameters are only adjustable if P1-13 = 0. This allows
complete flexibility over the drive control functions, and interaction with the
internal Function Block programming environment.
0
OFF
1
ON
See above
In combination with P9-18 – P9-20, allow selection of several speed reference
sources for common applications.
See above
0
Defined by P2-11
1
Function block program - digital
2
Function block program - analog
0
Defined by P2-13
1
Function block program - digital
2
Function block program - analog
0
Defined by P2-15
1
Function block program - digital
0
Defined by P2-18
1
Function block program - digital
0
Defined by P2-21
1
Function block program - digital
0
Defined by P3-05
1
Function block program - digital
0
Defined by P3-10
1
Function block program - digital
0
Defined by P4-06
1
Function block program - digital
0
Healthy : Tripped : Running
1
Function block program - digital
PACMotion VFD AC Variable Speed Drive User Guide
Default Notes
0
0
These parameters allow the
user to override the normal
parameter control source
for the associated function,
0
allowing interaction with
the internal Function Block
programming environment.
0
0
0
0
0
0
0
73